'''Talk Icon: Flashing at 1 second intervals''' | '''Talk Icon: Flashing at 1 second intervals''' | ||
− | + | Station has no connection to the AlphaCom server/exchange. | |
− | + | ||
− | + | Possible reasons: | |
− | + | * No connection to Ethernet | |
− | + | * Wrong AlphaCom XE IP address configured | |
− | + | * Invalid IP address | |
+ | * No gateway or wrong gateway to the AlphaCom server/exchange | ||
+ | |||
[[File:TCIS Indications 2.PNG|thumb|100px|left]] | [[File:TCIS Indications 2.PNG|thumb|100px|left]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Line 21: | Line 23: | ||
'''Talk Icon: Flashing at 5 second intervals''' | '''Talk Icon: Flashing at 5 second intervals''' | ||
− | + | Station connected but NOT registered in the AlphaCom server/exchange. | |
− | + | Reason: | |
− | + | * Station has not been programmed in AlphaPro | |
+ | |||
[[File:TCIS Indications 3.PNG|thumb|100px|left]] | [[File:TCIS Indications 3.PNG|thumb|100px|left]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Revision as of 13:42, 12 October 2016
LEDs on Front Plate
Status LEDs
- - Bell icon lights yellow when a call is placed and ringing
- - Talk icon lights green when a call is active and in conversation
- - Door icon lights red when the door is unlocked or relay is active
Talk Icon: Flashing at 1 second intervals Station has no connection to the AlphaCom server/exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom XE IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom server/exchange
Talk Icon: Flashing at 5 second intervals
Station connected but NOT registered in the AlphaCom server/exchange.
Reason:
- Station has not been programmed in AlphaPro
Status LEDs on PCB
Flashing 2 red + 1 green
- - Station has no connection to the AlphaCom server.
Flashing 1 red + 2 green
- - Station connected but NOT registered in the AlphaCom server.
Flashing 3 green
- - Station connected and registered in the AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- - Steady light: Ethernet connection OK
- - Flashing: Ethernet data traffic
- - No light: No Ethernet connection
Yellow LED
- - Steady light: 100 Mbit Ethernet connection
- - No light: 10 Mbit Ethernet connection