Difference between revisions of "TFIE Indication LEDs"
From Zenitel Wiki
(→LEDs on Front Plate) |
(→Status LEDs on PCB) |
||
Line 12: | Line 12: | ||
=Status LEDs on PCB= | =Status LEDs on PCB= | ||
− | [[File:TFIE Indications 2. | + | [[File:TFIE Board Indications 2.png|thumb|700px]] |
− | ''' | + | <br style="clear:both;" /> |
− | + | '''Flashing 2 red + 1 green:''' | |
+ | * Station has no connection to the AlphaCom server/exchange. | ||
− | ''' | + | '''Flashing 1 red + 2 green:''' |
− | + | * Station connected but NOT registered in the AlphaCom server/exchange. | |
− | ''' | + | '''Flashing 3 green''' |
− | + | * Station connected and registered in the AlphaCom server/exchange. | |
− | |||
− | |||
=Ethernet Activity & Speed LEDs on PCB= | =Ethernet Activity & Speed LEDs on PCB= |
Revision as of 12:45, 13 October 2016
LEDs on Front Plate
Power LED - Green:
- Steady light: Power is OK
Fault LED - Yellow:
- Steady light: Not used
- Flashing: Not registered/no connection to server
Call LED - Red:
- Steady light: In a conversation/call
Status LEDs on PCB
Flashing 2 red + 1 green:
- Station has no connection to the AlphaCom server/exchange.
Flashing 1 red + 2 green:
- Station connected but NOT registered in the AlphaCom server/exchange.
Flashing 3 green
- Station connected and registered in the AlphaCom server/exchange.
Ethernet Activity & Speed LEDs on PCB
Green LED
- - Steady light: Ethernet connection OK
- - Flashing: Ethernet data traffic
- - No light: No Ethernet connection
Yellow LED
- - Steady light: 100 Mbit Ethernet connection
- - No light: 10 Mbit Ethernet connection