Actions

Difference between revisions of "IP Flush Master and Headset"

From Zenitel Wiki

(Headset specifications)
(Headset specifications)
Line 18: Line 18:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
===Impedance:===
+
===Impedance ===
* Headset: Electret mic: 1-2 kohm, with phantom volatge 3-6 volt
+
* Electret microphone: 1-2 kohm, with phantom volatge 3-6 volt
* Loudspeaker: 120 – 1000 ohm
+
* Loudspeaker: 120–1000 ohm
  
 
+
=== PTT ===
PTT: Try contact, normally open (NO)
+
Try contact, normally open (NO)
  
 
Note that the PTT input on pin 11 and 12 is currently not supported. If PTT function is required, the PTT signal must be wired to one of the [[IP_Station_Board_Connections_and_Indications#P4_-_Inputs_and_Station_LED_2|three inputs on connector P4]] of the IP Flush Master.
 
Note that the PTT input on pin 11 and 12 is currently not supported. If PTT function is required, the PTT signal must be wired to one of the [[IP_Station_Board_Connections_and_Indications#P4_-_Inputs_and_Station_LED_2|three inputs on connector P4]] of the IP Flush Master.

Revision as of 11:27, 21 January 2015

Headset connection to IP Flush Master

This article describes how to connect headset to the IP Flush Master - 1008031000 or to the IP Master Station Kit - 1008093000.


The IP Flush Master station is fit with an RJ11 connector for headset connection. Insert the RJ11 plug of the headset into the upper port of the dual RJ11 ports on the lower left of the station. A regular PC style headset can be used. If the headset is not equipped with an RJ11 connector, an adapter must be made locally.

The headset will automatically be detected when connected, and a headset icon will appear in the top right corner of the display. The microphone and loudspeaker on the IP Flush Master panel will be disabled, and the audio routed to the headset.

Headset specifications

Connections

Connector J8
  • Pin 7 Mic+
  • Pin 8 Spk+
  • Pin 9 Spk-
  • Pin 10 Mic-
  • Pin 11 PTT Ground
  • Pin 12 PTT (Not currently supported by SW)


Impedance

  • Electret microphone: 1-2 kohm, with phantom volatge 3-6 volt
  • Loudspeaker: 120–1000 ohm

PTT

Try contact, normally open (NO)

Note that the PTT input on pin 11 and 12 is currently not supported. If PTT function is required, the PTT signal must be wired to one of the three inputs on connector P4 of the IP Flush Master.

Headset solution CRM-VH

The headset solution CRM-VH (Item number 2213100000) consists of a flush mounted Headset Connection Box and a headset. It is designed for the IP Flush Master station, and includes ON/OFF switch and a light, comfortable, single-sided mono headset with noise cancelling microphone.

The ON/OFF switch makes it possible to combine it with the handset (1008097100) for the IP Flush Master, and use it in loudspeaker mode.

The Headset Connection Box comes with a 50 cm patch cable for connection to the headset outlet in the IP Flush Master station. The dimension (HxWxD) is 96 x 96 x 80 mm.

CRM-VH Headset Connection Box
CRM-VH Headset


Headset AK5850HS

  • The headset AK5850HS (item 2330040026) comes with a boom microphone, curled cord and plug.
  • The Plugbox TA-22b (item 1008140225) comes with a PTT button and 10-meter long cable.
AK5850HS Headset with TA-22b plug box


The plugbox cable comes with three 2-poled IDC connectors. One can either remove the IDC connectors and terminate the cable with an RJ11 directly, or one can use a junction box as indicated on the drawing below.

TA-22b plug box - connection details


Configuring the PTT function

If the PTT function is to be used, the input "Key 1" of the IP Flush Master must be configured to activate M-key ON and OFF.

The input "Key 1" is normally reported as DAK 11. But if "Station Type" = CRM in AlphaPro (Users & Stations), the "Key 1" is reported as DAK 251.

Create an event from AlphaPro: In Users & Stations window, select the IP Flush Master from the list box, and press the button Events. Insert an event with the following properties:

Event for PTT function. Note that the Subevent must be set to 251 if the "Station Type" = CRM.


Action string:

$%chg(M,MREL) L%1.dir