Actions

Difference between revisions of "Tracing AlphaCom data communication"

From Zenitel Wiki

(Modify the configuration file for logging)
Line 18: Line 18:
  
 
# Specify the port number to be used for the trace connection (Note that this is a different port than the external application is using for MPC data)
 
# Specify the port number to be used for the trace connection (Note that this is a different port than the external application is using for MPC data)
# Remove the "#" in front of ... E.g remove the "#" in front of 74 to enable MPC data trace
+
# Remove the "#" in front of the protocol number to be traced. E.g remove the "#" in front of 74 to enable MPC data trace
 
# Save the file
 
# Save the file
 
# Rename the file from '''amx_trace_.txt''' to '''amx_trace.txt''' (I.e. remove the last "underscore").
 
# Rename the file from '''amx_trace_.txt''' to '''amx_trace.txt''' (I.e. remove the last "underscore").

Revision as of 20:37, 4 January 2016

As from AMC version 11.5.3.1B it is possible to trace various data protocols. Both input and output data can be traced, including time stamp. This can be useful for troubleshooting.

Modify the configuration file for logging

A configuration file for logging of data communication is located on the AMC-IP board, in the location /opt/amc/config/amx_trace_.txt. The configuration file is checked every 2 seconds and changes applied.

The PC program WinSCP is used to connect to the AlphaCom, open the configuration file and modify it.

In WinSCP create a New Site using:

  • File protocol: SFTP
  • Host name: IP address of the AlphaCom
  • Port number: 22
  • User name: root
  • Password: root password

Note: Port 22 (SSH) must be enabled in the AlphaWeb in System Configuration > Filters.

Log in, and navigate to /opt/amc/config/. Open the amx_trace_.txt file by doubleclicking it, and modify the file according to the information below:

  1. Specify the port number to be used for the trace connection (Note that this is a different port than the external application is using for MPC data)
  2. Remove the "#" in front of the protocol number to be traced. E.g remove the "#" in front of 74 to enable MPC data trace
  3. Save the file
  4. Rename the file from amx_trace_.txt to amx_trace.txt (I.e. remove the last "underscore").
Define the TCP port number to be used (here port 12345), and enable MPC trace by removing the "#" in front of 74


Define TCP port for logging in AlphaWeb

In AlphaWeb, System Configuration -> Filters, select Add Filters and add the same TCP port as defined in the configuration file above. Remember to Enable the port, and to Apply the settings.

Define in AlphaWeb the TCP port number to be used



Collect log data

Collect the trace data from AlphaCom by using the Telnet/SSH client program PuTTY.

Connection setup

  • Host Name: The IP Address of the AlphaCom (e.g 10.5.101.30)
  • Port: The port number defined in the configuration file (e.g. 12345)
  • Connection type: Raw
Connection setup in PuTTY


Log to file

In PuTTY select Session > Logging. Enable All session output, and choose a file name:

Enable logging to file


Now perform some activity in the AlphaCom which will generate MPC data (e.g. set up a call). Open the log file, and verify that there is data in the file. The log file should look something like this:

=~=~=~=~=~=~=~=~=~=~=~= PuTTY log 2015.12.21 15:28:47 =~=~=~=~=~=~=~=~=~=~=~=
74 2 1450708072 439 13  0200 F141 
74 2 1450708072 440 13  02D1 F141 
74 2 1450708072 730 13  02D0 F141 
74 2 1450708074 341 13  02D2 F141 
74 2 1450708074 482 13  0200 F102 
74 2 1450708074 483 28  0503 F141 F102 0000 0000 
74 2 1450708080 65 28  0504 F141 F102 0000 0000 
74 2 1450708082 854 13  0206 F102 
74 2 1450708082 856 13  0201 F102 
74 2 1450708082 866 13  0206 F141 
74 2 1450708082 867 13  0201 F141 
74 2 1450708091 368 13  0200 F102 
74 2 1450708091 369 13  0200 F140 
74 1 1450708091 369 13 I F102 F140
74 2 1450708091 458 28  0504 F102 F140 0000 0000 
74 1 1450708101 355 8 Q F140
74 2 1450708101 651 13  0206 F102 
74 2 1450708101 652 13  0201 F102 
74 2 1450708101 665 13  0206 F140 
74 2 1450708101 666 13  0201 F140 


Data Format Description

Example log string:

74 2 1450708091 458 28  0504 F102 F140 0000 0000
Parameter Description
74 Protocol number. 74 = MPC
2 Data From AMC (1 = read, 2 = write)
1450708091 Seconds since Epoch
458 Milliseconds
28 Number of bytes payload (one space after length not counted)
0504 F102 F140 0000 0000 Payload