Difference between revisions of "Light Industrial Master Station with Loudspeaker - 1007080000"
From Zenitel Wiki
Line 2: | Line 2: | ||
[[image:1007080000.PNG|thumb|250px|Light Industrial Master Station]] | [[image:1007080000.PNG|thumb|250px|Light Industrial Master Station]] | ||
− | == | + | The Light Industrial Master Station is an analog intercom station. It is connected to an [[ASLT|ASLT line card]] in an [[AlphaCom XE7]], [[AlphaCom XE20]] or [[AlphaCom XE26]] server using 2 pairs of wires. |
+ | |||
+ | == Highlights == | ||
* Fully equipped splashproof master station with free access to all extensions and features | * Fully equipped splashproof master station with free access to all extensions and features | ||
* Flame- and chip-resistant plastic casing. Key board foil of UV-cured PVC. Resistant to corrosive fluids | * Flame- and chip-resistant plastic casing. Key board foil of UV-cured PVC. Resistant to corrosive fluids | ||
Line 10: | Line 12: | ||
* Built-in 10W (8 Ohm) VOX operated power amplifier for external loudspeaker | * Built-in 10W (8 Ohm) VOX operated power amplifier for external loudspeaker | ||
− | == | + | == Dimensional Drawing == |
[[File:1007080000-dimensions 0.jpg|600px]] | [[File:1007080000-dimensions 0.jpg|600px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | == | + | == Connections == |
For server end connection details see [[ASLT - AlphaCom Subscriber Line Board]] | For server end connection details see [[ASLT - AlphaCom Subscriber Line Board]] | ||
Line 20: | Line 22: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | === | + | === Handset connection === |
When handset is connected, open shunt S8 and S11. <br> | When handset is connected, open shunt S8 and S11. <br> | ||
[[File:7080_handset_conn.PNG|thumb|left|500px]] | [[File:7080_handset_conn.PNG|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | === | + | === Handset troubleshooting === |
'''Symptom:''' | '''Symptom:''' | ||
Line 36: | Line 38: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | === | + | == Related articles == |
+ | * [http://www.zenitel.com/product/light-industrial-master-station Additional Documentation on Zenitel.com] | ||
[[Category: Analogue 4-wire Stations]] | [[Category: Analogue 4-wire Stations]] |
Revision as of 14:58, 15 August 2018
The Light Industrial Master Station is an analog intercom station. It is connected to an ASLT line card in an AlphaCom XE7, AlphaCom XE20 or AlphaCom XE26 server using 2 pairs of wires.
Contents
Highlights
- Fully equipped splashproof master station with free access to all extensions and features
- Flame- and chip-resistant plastic casing. Key board foil of UV-cured PVC. Resistant to corrosive fluids
- Electret microphone and red microphone live lamp
- Screw terminals for easy connection of installation cables
- Built-in loudspeaker and possibility to connect an external speaker. Sound level adjustable with a potentiometer inside the station
- Built-in 10W (8 Ohm) VOX operated power amplifier for external loudspeaker
Dimensional Drawing
Connections
For server end connection details see ASLT - AlphaCom Subscriber Line Board
Handset connection
When handset is connected, open shunt S8 and S11.
Handset troubleshooting
Symptom:
When an industrial station type 100 7080 000 is equipped with a handset there is a knows issue related to the handset operation: when the handset is replaced (on-hook) during conversation, the conversation does not cancel.
Solution:
A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V.