Actions

Difference between revisions of "IP Hotline Connections"

From Zenitel Wiki

m (1 revision imported)
Line 1: Line 1:
== Introduction ==
+
==INCA Based==
 +
=== Introduction ===
 
The table below is an overview of the main connectors involved when installing the IP Hotline Station.
 
The table below is an overview of the main connectors involved when installing the IP Hotline Station.
  
Line 17: Line 18:
  
 
[[File:IP Master Station Kit.PNG|right|300px]]
 
[[File:IP Master Station Kit.PNG|right|300px]]
== Power Supply ==
+
=== Power Supply ===
 
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.  
 
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.  
  
Line 24: Line 25:
 
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
 
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
  
== Network Connection ==
+
=== Network Connection ===
 
There are two RJ45 ports on the IP Hotline Station:  
 
There are two RJ45 ports on the IP Hotline Station:  
 
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
 
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
 
:* AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
 
:* AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
  
== Input/Output Connections ==
+
=== Input/Output Connections ===
 
There are I/O connection options for the IP Hotline Station. These I/O connections include:
 
There are I/O connection options for the IP Hotline Station. These I/O connections include:
  
=== P3 - External Loudspeaker, Relay Output and External Power Input ===
+
==== P3 - External Loudspeaker, Relay Output and External Power Input ====
 
6-pin plug-on screw terminal for external connections.
 
6-pin plug-on screw terminal for external connections.
 
[[File:IP Master Board 2.PNG|left|thumb|200px|P3]]
 
[[File:IP Master Board 2.PNG|left|thumb|200px|P3]]
Line 40: Line 41:
 
*Pin 5/6  Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.
 
*Pin 5/6  Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.
  
=== P4 - Inputs and Station LED ===
+
==== P4 - Inputs and Station LED ====
 
6-pin plug-on screw terminal for external connections.
 
6-pin plug-on screw terminal for external connections.
 
[[File:IP Master Board 3.PNG|left|thumb|200px|P4]]
 
[[File:IP Master Board 3.PNG|left|thumb|200px|P4]]
Line 49: Line 50:
 
*Pin 5/6  Station LED for call message info. (Pin 6 is positive.)
 
*Pin 5/6  Station LED for call message info. (Pin 6 is positive.)
  
=== J10 - Microphone ===
+
==== J10 - Microphone ====
 
Connection to handset microphone
 
Connection to handset microphone
 
[[File:IP Master Board 10.PNG|left|thumb|200px|J10]]
 
[[File:IP Master Board 10.PNG|left|thumb|200px|J10]]
Line 62: Line 63:
  
 
[[Category: INCA Connections]]
 
[[Category: INCA Connections]]
 +
[[Category: Turbine Connections]]

Revision as of 08:58, 22 February 2019

INCA Based

Introduction

The table below is an overview of the main connectors involved when installing the IP Hotline Station.

LAN (P1) 10/100 Mbps RJ45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX (P2) 10/100 Mbps RJ45 port for auxilliary equipment such as PC or IP Camera.
Input/Output Pluggable screw terminal
Local Power Pluggable screw terminal, 17-27 VDC Idle 4W, max. 8W

To access these connectors the front cover must be removed.

IP Master Station Kit.PNG

Power Supply

The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Hotline Station can be connected to a 24 VDC local power supply.

See Related Article INCA Master Station Kit Board Connectors for local power supply connections.

Network Connection

There are two RJ45 ports on the IP Hotline Station:

  • LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
  • AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.

Input/Output Connections

There are I/O connection options for the IP Hotline Station. These I/O connections include:

P3 - External Loudspeaker, Relay Output and External Power Input

6-pin plug-on screw terminal for external connections.

P3


  • Pin 1/2 Connection to the loudspeaker of the handset
  • Pin 3/4 Internal NO relay contact for additional call indication etc.
  • Pin 5/6 Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.

P4 - Inputs and Station LED

6-pin plug-on screw terminal for external connections.

P4


  • Pin 1/4 Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
  • Pin 2/4 Input 2 (optional)
  • Pin 3/4 Input 3 (optional)
  • Pin 5/6 Station LED for call message info. (Pin 6 is positive.)

J10 - Microphone

Connection to handset microphone

J10


  • Pin 1 MIC+
  • Pin 2 MIC-

Note that the microphone selection switch next to connector J10 should be in the left position, labeled "Int.".