Difference between revisions of "IP Hotline Connections"
From Zenitel Wiki
m (1 revision imported) |
|||
Line 1: | Line 1: | ||
− | == Introduction == | + | ==INCA Based== |
+ | === Introduction === | ||
The table below is an overview of the main connectors involved when installing the IP Hotline Station. | The table below is an overview of the main connectors involved when installing the IP Hotline Station. | ||
Line 17: | Line 18: | ||
[[File:IP Master Station Kit.PNG|right|300px]] | [[File:IP Master Station Kit.PNG|right|300px]] | ||
− | == Power Supply == | + | === Power Supply === |
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. | The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. | ||
Line 24: | Line 25: | ||
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections. | See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections. | ||
− | == Network Connection == | + | === Network Connection === |
There are two RJ45 ports on the IP Hotline Station: | There are two RJ45 ports on the IP Hotline Station: | ||
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server. | :* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server. | ||
:* AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera. | :* AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera. | ||
− | == Input/Output Connections == | + | === Input/Output Connections === |
There are I/O connection options for the IP Hotline Station. These I/O connections include: | There are I/O connection options for the IP Hotline Station. These I/O connections include: | ||
− | === P3 - External Loudspeaker, Relay Output and External Power Input === | + | ==== P3 - External Loudspeaker, Relay Output and External Power Input ==== |
6-pin plug-on screw terminal for external connections. | 6-pin plug-on screw terminal for external connections. | ||
[[File:IP Master Board 2.PNG|left|thumb|200px|P3]] | [[File:IP Master Board 2.PNG|left|thumb|200px|P3]] | ||
Line 40: | Line 41: | ||
*Pin 5/6 Connect 24 VDC for station power if PoE is not used. Pin 6 is positive. | *Pin 5/6 Connect 24 VDC for station power if PoE is not used. Pin 6 is positive. | ||
− | === P4 - Inputs and Station LED === | + | ==== P4 - Inputs and Station LED ==== |
6-pin plug-on screw terminal for external connections. | 6-pin plug-on screw terminal for external connections. | ||
[[File:IP Master Board 3.PNG|left|thumb|200px|P4]] | [[File:IP Master Board 3.PNG|left|thumb|200px|P4]] | ||
Line 49: | Line 50: | ||
*Pin 5/6 Station LED for call message info. (Pin 6 is positive.) | *Pin 5/6 Station LED for call message info. (Pin 6 is positive.) | ||
− | === J10 - Microphone === | + | ==== J10 - Microphone ==== |
Connection to handset microphone | Connection to handset microphone | ||
[[File:IP Master Board 10.PNG|left|thumb|200px|J10]] | [[File:IP Master Board 10.PNG|left|thumb|200px|J10]] | ||
Line 62: | Line 63: | ||
[[Category: INCA Connections]] | [[Category: INCA Connections]] | ||
+ | [[Category: Turbine Connections]] |
Revision as of 08:58, 22 February 2019
Contents
INCA Based
Introduction
The table below is an overview of the main connectors involved when installing the IP Hotline Station.
LAN (P1) | 10/100 Mbps RJ45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line. |
AUX (P2) | 10/100 Mbps RJ45 port for auxilliary equipment such as PC or IP Camera. |
Input/Output | Pluggable screw terminal |
Local Power | Pluggable screw terminal, 17-27 VDC Idle 4W, max. 8W |
To access these connectors the front cover must be removed.
Power Supply
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
If PoE is not available, the IP Hotline Station can be connected to a 24 VDC local power supply.
See Related Article INCA Master Station Kit Board Connectors for local power supply connections.
Network Connection
There are two RJ45 ports on the IP Hotline Station:
- LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
- AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
Input/Output Connections
There are I/O connection options for the IP Hotline Station. These I/O connections include:
P3 - External Loudspeaker, Relay Output and External Power Input
6-pin plug-on screw terminal for external connections.
- Pin 1/2 Connection to the loudspeaker of the handset
- Pin 3/4 Internal NO relay contact for additional call indication etc.
- Pin 5/6 Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.
P4 - Inputs and Station LED
6-pin plug-on screw terminal for external connections.
- Pin 1/4 Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
- Pin 2/4 Input 2 (optional)
- Pin 3/4 Input 3 (optional)
- Pin 5/6 Station LED for call message info. (Pin 6 is positive.)
J10 - Microphone
Connection to handset microphone
- Pin 1 MIC+
- Pin 2 MIC-
Note that the microphone selection switch next to connector J10 should be in the left position, labeled "Int.".
For more details see INCA Substation Board Connectors.