Event description
Event Owner: | A station or an UDP group |
Event type: | 07 - Conversation Incoming |
Subevent: | N/A |
When change to ON: | Conversation start, or conversation resumed after parked by peer station (inquiry, door opening) |
When change to OFF: | Conversation end, or conversation parked by peer station (inquiry, door opening). |
When related to: | The calling station |
Application
- CRM IV LED control
- Call logging
- CCTV interfacing
Additional information
- - Related event: "08 Conversation Outgoing"
"Door opening" Door station - Control station
- - If the Conversation Incoming event relates to the control station the event stays ON also during door opening action.
- - If the Conversation Incoming event relates to the door station the event will go OFF during activation of the door opening relay.