Difference between revisions of "AlphaPro 12 - Error messages"
From Zenitel Wiki
Line 6: | Line 6: | ||
* ''The remote server returned an error: (404) Not Found'': AlphaPro v.12 is used towards AlphaCom v. 11. | * ''The remote server returned an error: (404) Not Found'': AlphaPro v.12 is used towards AlphaCom v. 11. | ||
* ''The remote server returned an error: (500) Internal Server Error'': The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a [[Redundant Servers (High Availability)|redundant system]] with two AlphaCom servers) | * ''The remote server returned an error: (500) Internal Server Error'': The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a [[Redundant Servers (High Availability)|redundant system]] with two AlphaCom servers) | ||
− | * ''Unable to connect to x.x.x.x'' (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only) | + | * ''Unable to connect to x.x.x.x'' (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in [[AlphaWeb#Filters|Filters setting]] in Web interface (Applies to SendAll/SendChg operations only) |
− | * ''Unable to connect to the remote server'': TCP port 80 (HTTP) is disabled in Filters setting in Web interface | + | * ''Unable to connect to the remote server'': TCP port 80 (HTTP) is disabled in [[AlphaWeb#Filters|Filters setting]] in Web interface |
Revision as of 10:47, 18 December 2019
If AlphaPro is not able to communicate with the AlphaCom server, there are several possible reasons:
AlphaPro 12 error messages:
- The remote server returned an error: (401) Unauthorized: Wrong username/password for logging in
- Unable to connect to the remote server: Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom
- The remote server returned an error: (404) Not Found: AlphaPro v.12 is used towards AlphaCom v. 11.
- The remote server returned an error: (500) Internal Server Error: The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a redundant system with two AlphaCom servers)
- Unable to connect to x.x.x.x (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only)
- Unable to connect to the remote server: TCP port 80 (HTTP) is disabled in Filters setting in Web interface