This article describes how to upgrade the software in Flowire devices [[FCDC-1]] and [[FCDC-2]].
  
This is a step by step guide to upgrading the software in Flowire through the serial interface.  
+
For upgrade procedure for [[FCDC-3]], see [[FCDC-3 - Software Upgrade Procedure|here]].
  
== Requirements ==
+
There are different ways, depending on the current software:
 +
* If the current software is 4.x, the upgrade can be done from the web page of the Flowire unit, or by using the [[IMT - Discover & Upgrade|VS-IMT tool]]
 +
* If the current software is 1.x or 2.x, the upgrade must be done via the serial interface of the Flowire unit
 +
 
 +
== How to determine the current software version ==
 +
 
 +
*Hardware version 0105 (Item: 1008080110.0105) and newer has version 4.x installed from factory, and can be upgraded via the web interface or via the VS-IMT tool.
 +
*Hardware version 0104 (Item: 1008080110.0104) and older has version 1.x or 2.x installed from factory, and must be updated via the serial interface.
 +
 
 +
 
 +
You can also check the Flowire unit from you PC: If you can ping the device, but not access it via the web browser, it is an old software version and it must be upgraded via the serial interface.
 +
 
 +
== Upgrading from software version 4.x ==
 +
Flowire units with software version 4.x can be upgraded through the web interface of the Flowire or using the [[IMT - Discover & Upgrade|VS-IMT tool]].
 +
 
 +
The Flowire units are automatically assigned an IP address from the network if there is a DHCP server present. You can then access the Flowire units web interface one by one and perform the upgrade.
 +
 
 +
If there is no DHCP server on the network, the Flowire units will by default have a static IP address 169.254.1.10. In this case there will be multiple Flowire units with the same IP address on the network, and you need to isolate the Flowire unit which is going to be upgraded from the others in the network. 
 +
 
 +
[[File:Flowire Connections 2.PNG|thumb|left|500px|Isolating the Flowire units one by one]]
 +
<br style="clear:both;" />
 +
 
 +
Although it is not necessary for the Flowire to perform its function, it is good practice to change the static IP to something unique at the same time, for easier maintenance in the future.
 +
 
 +
The [[Downloads#Flowire|latest software package]] must be downloaded from the download site. Unzip the files to a folder.
 +
 
 +
'''1) Requirements'''
 
* Windows PC
 
* Windows PC
* TFTPS server, for example Tftpd32 or Tftpd64 by Ph. Jounin (http://tftpd32.jounin.net)
+
* DHCP server. (If there is no DHCP server in the network, a temporarily DHCP server can be set up using for example Tftpd32 or Tftpd64 by Ph. Jounin (http://tftpd32.jounin.net)
 +
* Simple switch
 +
* Ethernet cables
 +
* Flowire unit(s)
 +
* Flowire power supply
 +
 
 +
''If there is a DHCP server already in the network, please skip to point 4.''
 +
 
 +
'''2) PC setup'''
 +
Set static IP address 169.254.1.2 on your PC
 +
[[File:Flowire Upgrade 6.PNG|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 +
'''3) DHCP server setup'''
 +
* Start the Tftpd
 +
* Click the settings button:
 +
[[File:Flowire Upgrade 7.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 
 +
* Choose the DHCP tab and set these settings:
 +
[[File:Flowire Upgrade 8.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 
 +
* Choose the Global tab and make sure TFTP Server and TFTP Client are disabled:
 +
[[File:Flowire Upgrade 9.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 
 +
* Finish with OK
 +
* From the main window choose the DHCP server tab to monitor the IP address given to the Flowire. Choose the PC LAN port as the server interface:
 +
[[File:Flowire Upgrade 10.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 
 +
'''4a) Upgrading from IMT'''
 +
 
 +
See article [[IMT - Discover & Upgrade]]
 +
 
 +
''' 4b) Upgrading from Web server'''
 +
* Start the TFTP server and '''Browse''' to the folder where the software files are stored.
 +
[[File:FlowireTFTP.png|thumb|left|500px|TFTP server setup]]
 +
<br style="clear:both;" />
 +
 
 +
Use a standard web browser and enter the IP address of the Flowire (e.g. 169.254.1.10) in the address field.
 +
[[File:Flowire Upgrade.PNG|thumb|left|500px|Flowire upgrade - enter TFTP server address]]
 +
<br style="clear:both;" />
 +
 
 +
Enter the TFTP server IP address and select '''Upgrade'''.
 +
 
 +
'''Upgrade''': Upgrades the software and keeps all custom settings
 +
'''Full Upgrade''': Upgrades the software and performs a reset to factory settings
 +
 
 +
As a precaution you should set the NMK again after update
 +
 
 +
== Upgrade from software version 1.x or 2.x ==
 +
 
 +
Flowire units running software version 1.x or 2.x must be upgraded via its serial interface.
 +
 
 +
=== Requirements ===
 +
The following equipment is required to perform the upgrade:
 +
* TFTP server, for example Tftpd32 or Tftpd64 by Ph. Jounin (http://tftpd32.jounin.net)
 
* Telnet software, for example PuTTY by Simon Tatham (http://www.chiark.greenend.org.uk/~sgtatham/putty/)
 
* Telnet software, for example PuTTY by Simon Tatham (http://www.chiark.greenend.org.uk/~sgtatham/putty/)
* Simple network switch
+
* A network switch
* 2 Ethernet cables
+
* USB-Serial cable with JTAG connector*
* Special USB-Serial cable with JTAG connector
+
* Flowire unit with power supply
* Flowire unit
 
* Flowire power supply
 
 
* Software for the Flowire. [[Downloads#Flowire|Download the software here.]]
 
* Software for the Flowire. [[Downloads#Flowire|Download the software here.]]
  
== Create the special USB-Serial cable ==
+
=== USB-Serial cable ===
* You need an USB to RS232 cable with 3,3V TTL level. For example: http://au.element14.com/ftdi/ttl-232r-3v3/connector-type-a/dp/1329311
+
A special USB to Serial cable has to be used for the software upgrade. The cable can be made out of two items:
* You also need a ribbon cable. Suggested type: http://no.farnell.com/harwin/m50-9011042/receptacle-to-dip-150mm-20way/dp/2289813
+
* An USB to RS232 cable with 3,3V TTL level. For example: http://au.element14.com/ftdi/ttl-232r-3v3/connector-type-a/dp/1329311
* With these two items, create an adapter cable to connect to the debug connector on Flowire:
+
* A ribbon cable. Suggested type: http://no.farnell.com/harwin/m50-9011042/receptacle-to-dip-150mm-20way/dp/2289813
 +
 
 +
With these two items, make an adapter cable which connects the debug connector of the Flowire to the USB port of the PC:
 
[[File:Flowire cable.PNG|thumb|left|500px|Flowire cable]]
 
[[File:Flowire cable.PNG|thumb|left|500px|Flowire cable]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
* On the Flowire, you must connect to these pins:
+
* On the Flowire, connect to these pins:
** 7: GND
+
** Pin 7: GND
** 8: UART1_TX – Connect this to Rx on the serial cable
+
** Pin 8: TX (Transmit) – Connect this to Rx on the serial cable
** 16: UART1_RX – Connect this to Tx on the serial cable
+
** Pin 16: RX (Receive) – Connect this to Tx on the serial cable
 
[[File:FlowirePins.PNG|thumb|left|500px|Flowire pinning]]
 
[[File:FlowirePins.PNG|thumb|left|500px|Flowire pinning]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
== PC setup ==
+
=== PC setup ===
*Set static IP address 169.254.1.2 on your PC
+
*Set the IP address of your computer to 169.254.1.2, subnet mask 255.255.255.0:
  
 
[[File:FlowirePCSetup.png|thumb|left|300px|Set static IP address 169.254.1.2 on your PC]]
 
[[File:FlowirePCSetup.png|thumb|left|300px|Set static IP address 169.254.1.2 on your PC]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
* Connect the USB-Serial cable
+
* Connect the USB-Serial cable to the USB port of the PC
* In the Control Panel, open the "Device Manager" to see which serial port is being used. It will be listed under “Ports (COM & LPT)as USB Serial COM port #x, where x represents the COM port number. Double click it and change the port settings from 9600 baud to 115200 baud.
+
* In the '''Control Panel''', open the '''Device Manager''' to see which serial port has been assigned. It will be listed under''' Ports (COM & LPT)''' as USB Serial COM port #x, where x represents the COM port number. Double click it and change the port settings from 9600 baud to 115200 baud.
  
== TFTP server setup ==
+
=== TFTP server setup ===
* Start the Tftpd
+
* Start the Tftpd program on the PC
* From the main window browse to the folder where the software files are kept. Choose the PC LAN port as the server interface:
+
* From the main window browse to the folder where the software files are stored. Choose the PC LAN port as the server interface:
 
[[File:FlowireTFTP.png|thumb|left|500px|TFTP server setup]]
 
[[File:FlowireTFTP.png|thumb|left|500px|TFTP server setup]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
+
=== Physical setup ===
== Physical setup ==
 
 
* ''Do not'' connect the power supply to the Flowire unit yet
 
* ''Do not'' connect the power supply to the Flowire unit yet
 
* Take of the top lid of the Flowire by unscrewing the two screws
 
* Take of the top lid of the Flowire by unscrewing the two screws
 
* Locate the JTAG and connect the cable, cable pointing away from the PCB
 
* Locate the JTAG and connect the cable, cable pointing away from the PCB
* Connect the PC to the switch using a LAN cable.
+
* Connect the PC to the switch using an ethernet cable
* Connect the Flowire to the switch using a LAN cable
+
* Connect the Flowire to the switch using an ethernet cable
  
 
[[File:FlowireConnections.PNG|thumb|left|500px|Physical setup]]
 
[[File:FlowireConnections.PNG|thumb|left|500px|Physical setup]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
+
=== Upgrade through Telnet ===
== Telnet setup ==
+
==== Telnet Setup ====
 
* Open PuTTY
 
* Open PuTTY
* Choose Connection Type Serial, change Speed to 115200 and make sure it has the right COM port number:
+
* Choose Connection Type '''Serial''', change Speed to '''115200''' and make sure it has the right COM port number:
  
 
[[File:FlowirePutty.png|thumb|left|500px|Telnet setup]]
 
[[File:FlowirePutty.png|thumb|left|500px|Telnet setup]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
* While holding down the space bar (or actually any key), power up the Flowire. You should see data in the command window. Once you see data release the space bar.
+
When all settings are correct press the '''Open''' button. A new command window will open.
 +
 
 +
==== Version check ====
 +
By running this command you can see the current software version:
 +
cat /etc/version
 +
 
 +
==== Upgrade ====
 +
* While holding down the space bar (or actually any key), power up the Flowire. You should see data in the command window. Once you see data, release the space bar.
 +
[[File:Flowire Upgrade 2.PNG|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 
 
*Enter these commands, one at a time, and press [Enter] after each command:
 
*Enter these commands, one at a time, and press [Enter] after each command:
 
** ''setenv serverip 169.254.1.2''
 
** ''setenv serverip 169.254.1.2''
Line 77: Line 170:
 
** ''reset''
 
** ''reset''
  
 +
Example:
 +
[[File:Flowire Upgrade 3.PNG|thumb|left|500px]]
 +
<br style="clear:both;" />
  
 
'''TIP!''' Mark the text line and copy it (right click > copy, or Ctrl+C). In the PuTTY window right click with the mouse and the text is instantly pasted. Hit [enter]. Copy/paste one line at a time.
 
'''TIP!''' Mark the text line and copy it (right click > copy, or Ctrl+C). In the PuTTY window right click with the mouse and the text is instantly pasted. Hit [enter]. Copy/paste one line at a time.
Line 83: Line 179:
 
** ''cat /proc/net/plc/version''
 
** ''cat /proc/net/plc/version''
 
* The procedure is now finished. The Flowire can be disconnected and the next unit can be upgraded.
 
* The procedure is now finished. The Flowire can be disconnected and the next unit can be upgraded.
 +
 +
==Troubleshooting==
 +
In the case the upgrade is not successful it may be due to a windows setting.
 +
 +
*For Windows XP: [http://www.sysprobs.com/enable-ping-in-xp http://www.sysprobs.com/enable-ping-in-xp]
 +
 +
*For Windows7: [http://www.sysprobs.com/enable-ping-reply-windows-7 http://www.sysprobs.com/enable-ping-reply-windows-7]
 +
 +
*For Windows10: [http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server]
 +
 +
 +
[[Category: Flowire]]

Latest revision as of 08:43, 16 August 2022

This article describes how to upgrade the software in Flowire devices FCDC-1 and FCDC-2.

For upgrade procedure for FCDC-3, see here.

There are different ways, depending on the current software:

  • If the current software is 4.x, the upgrade can be done from the web page of the Flowire unit, or by using the VS-IMT tool
  • If the current software is 1.x or 2.x, the upgrade must be done via the serial interface of the Flowire unit

How to determine the current software version

  • Hardware version 0105 (Item: 1008080110.0105) and newer has version 4.x installed from factory, and can be upgraded via the web interface or via the VS-IMT tool.
  • Hardware version 0104 (Item: 1008080110.0104) and older has version 1.x or 2.x installed from factory, and must be updated via the serial interface.


You can also check the Flowire unit from you PC: If you can ping the device, but not access it via the web browser, it is an old software version and it must be upgraded via the serial interface.

Upgrading from software version 4.x

Flowire units with software version 4.x can be upgraded through the web interface of the Flowire or using the VS-IMT tool.

The Flowire units are automatically assigned an IP address from the network if there is a DHCP server present. You can then access the Flowire units web interface one by one and perform the upgrade.

If there is no DHCP server on the network, the Flowire units will by default have a static IP address 169.254.1.10. In this case there will be multiple Flowire units with the same IP address on the network, and you need to isolate the Flowire unit which is going to be upgraded from the others in the network.

Isolating the Flowire units one by one


Although it is not necessary for the Flowire to perform its function, it is good practice to change the static IP to something unique at the same time, for easier maintenance in the future.

The latest software package must be downloaded from the download site. Unzip the files to a folder.

1) Requirements

  • Windows PC
  • DHCP server. (If there is no DHCP server in the network, a temporarily DHCP server can be set up using for example Tftpd32 or Tftpd64 by Ph. Jounin (http://tftpd32.jounin.net)
  • Simple switch
  • Ethernet cables
  • Flowire unit(s)
  • Flowire power supply
If there is a DHCP server already in the network, please skip to point 4.

2) PC setup Set static IP address 169.254.1.2 on your PC

Flowire Upgrade 6.PNG


3) DHCP server setup

  • Start the Tftpd
  • Click the settings button:
Flowire Upgrade 7.png


  • Choose the DHCP tab and set these settings:
Flowire Upgrade 8.png


  • Choose the Global tab and make sure TFTP Server and TFTP Client are disabled:
Flowire Upgrade 9.png


  • Finish with OK
  • From the main window choose the DHCP server tab to monitor the IP address given to the Flowire. Choose the PC LAN port as the server interface:
Flowire Upgrade 10.png


4a) Upgrading from IMT

See article IMT - Discover & Upgrade

4b) Upgrading from Web server

  • Start the TFTP server and Browse to the folder where the software files are stored.
TFTP server setup


Use a standard web browser and enter the IP address of the Flowire (e.g. 169.254.1.10) in the address field.

Flowire upgrade - enter TFTP server address


Enter the TFTP server IP address and select Upgrade.

Upgrade: Upgrades the software and keeps all custom settings
Full Upgrade: Upgrades the software and performs a reset to factory settings

As a precaution you should set the NMK again after update

Upgrade from software version 1.x or 2.x

Flowire units running software version 1.x or 2.x must be upgraded via its serial interface.

Requirements

The following equipment is required to perform the upgrade:

USB-Serial cable

A special USB to Serial cable has to be used for the software upgrade. The cable can be made out of two items:

With these two items, make an adapter cable which connects the debug connector of the Flowire to the USB port of the PC:

Flowire cable


  • On the Flowire, connect to these pins:
    • Pin 7: GND
    • Pin 8: TX (Transmit) – Connect this to Rx on the serial cable
    • Pin 16: RX (Receive) – Connect this to Tx on the serial cable
Flowire pinning


PC setup

  • Set the IP address of your computer to 169.254.1.2, subnet mask 255.255.255.0:
Set static IP address 169.254.1.2 on your PC


  • Connect the USB-Serial cable to the USB port of the PC
  • In the Control Panel, open the Device Manager to see which serial port has been assigned. It will be listed under Ports (COM & LPT) as USB Serial COM port #x, where x represents the COM port number. Double click it and change the port settings from 9600 baud to 115200 baud.

TFTP server setup

  • Start the Tftpd program on the PC
  • From the main window browse to the folder where the software files are stored. Choose the PC LAN port as the server interface:
TFTP server setup


Physical setup

  • Do not connect the power supply to the Flowire unit yet
  • Take of the top lid of the Flowire by unscrewing the two screws
  • Locate the JTAG and connect the cable, cable pointing away from the PCB
  • Connect the PC to the switch using an ethernet cable
  • Connect the Flowire to the switch using an ethernet cable
Physical setup


Upgrade through Telnet

Telnet Setup

  • Open PuTTY
  • Choose Connection Type Serial, change Speed to 115200 and make sure it has the right COM port number:
Telnet setup


When all settings are correct press the Open button. A new command window will open.

Version check

By running this command you can see the current software version:

cat /etc/version

Upgrade

  • While holding down the space bar (or actually any key), power up the Flowire. You should see data in the command window. Once you see data, release the space bar.
Flowire Upgrade 2.PNG


  • Enter these commands, one at a time, and press [Enter] after each command:
    • setenv serverip 169.254.1.2
    • setenv ipaddr 169.254.1.10
    • protect off all
    • tftp 0x40100000 u-boot218.bin
    • erase 0x30000000 0x3002FFFF
    • cp.b 0x40100000 0x30000000 0x30000
    • tftp 0x40100000 jffs2-spc
    • erase 0x30040000 0x3013FFFF
    • cp.b 0x40100000 0x30040000 0x100000
    • tftp 0x40100000 linux-spc
    • erase 0x30140000 0x3049FFFF
    • cp.b 0x40100000 0x30140000 0x360000
    • reset

Example:

Flowire Upgrade 3.PNG


TIP! Mark the text line and copy it (right click > copy, or Ctrl+C). In the PuTTY window right click with the mouse and the text is instantly pasted. Hit [enter]. Copy/paste one line at a time.

  • When the Flowire is back online you can login with root.
  • By running this command you can see the new software version:
    • cat /proc/net/plc/version
  • The procedure is now finished. The Flowire can be disconnected and the next unit can be upgraded.

Troubleshooting

In the case the upgrade is not successful it may be due to a windows setting.