Actions

Difference between revisions of "TCIx Connections"

From Zenitel Wiki

m (Asle moved page TCIS Connections to TCIx Connections)
 
(61 intermediate revisions by 4 users not shown)
Line 1: Line 1:
[[File:TCIS Connections 1.PNG|right]]
+
{{AEIPS}}
This article describers all Turbine Compact IP Standard Station connections.
+
===Network Connection===
 
+
Connect the Turbine Compact Station to the data network via the RJ45 plug. The unit supports Power over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line. If PoE is not available, the Turbine Compact Station can be powered from a 24 VDC local power supply.  
The Turbine Compact IP station has a RJ-45 PoE/LAN port, and 6-pin & 10-pin external connectors.
+
[[File:TCIS-X top.PNG|thumb|left|250px|Turbine Compact top view]]
 
 
{|border="1"
 
|Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
 
|-
 
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
 
|-
 
|Relays || There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W.
 
|-
 
|Input/Output || 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.
 
|-
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|}
 
 
 
'''Note!''' Use cables crimped with ferrules for terminal block connectors
 
 
 
* When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
 
* To make the station speak its IP address, press the call button on the station.
 
[[File:TCIS Connections 2.PNG]]
 
 
 
<br style="clear:both;" />
 
 
 
=PCB - Front=
 
[[File:TCIS Connections 3.PNG]]
 
 
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
[[File:TCIS Connections 4.PNG|thumb|700px]]
+
=== External Connectors ===
'''P1''' RJ45 PoE port for 10/100 Mbit Ethernet connection.
+
<!--[[File:TCIS Connections 1.PNG|right|250px|thumb|External Connectors on Turbine IP Station]]-->
:The station can be powered from this port if the line supports Power over Ethernet (PoE).
+
<gallery mode="traditional" widths=300px heights=300px perrow=2>
 
+
File:TCIS-X rear.PNG|TCIS and TCIV
 +
File:TCIV+ rear.png|TCIV+
 +
</gallery>
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
[[File:TCIS Connections 5.PNG|thumb|700px]]
+
*'''Ethernet/Power''': 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
'''P2'''6-pin plug-on terminal for external connections.
+
*'''Secondary Power''': 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
:Pin 1/2  24 VDC for external secondary power if PoE is not used. Pin 1 is positive.
+
*'''Relays''': There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
:Pin 3  COM relay
+
*'''Input/Output''': 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
:Pin 4  NO relay
+
*'''Audio Line Out''': A balanced 600 ohm audio line out with induction loop signal
:Pin 5  NC relay
 
 
 
<br style="clear:both;" />
 
  
[[File:TCIS Connections 6.PNG|thumb|700px]]
+
===Input/Output Connections===
'''P3'''  10-pin plug-on terminal for external connections.
+
There are 6 I/O connection options for the Turbine Compact Station.
:Pin 1  5.3V
+
These connections are used as relay contacts for door lock control and external I/O devices.  
:Pin 2  GND
 
:Pin 3  Button Input or LED Driver
 
:Pin 4  Button Input or LED Driver
 
:Pin 5  Button Input or LED Driver
 
:Pin 6  Button Input or LED Driver
 
:Pin 7  Button Input or LED Driver
 
:Pin 8  Button Input or LED Driver
 
:Pin 9  600 ohm balanced line out +
 
:Pin 10  600 ohm balanced line out -1
 
  
<br style="clear:both;" />
+
For more details see [[Turbine Compact Board Connectors]]
 
 
[[File:TCIS Connections 7.PNG|thumb|700px]]
 
'''P4'''  Loudspeaker & Electret microphone
 
:Pin 1  10W Speaker amplifier +
 
:Pin 2  10W Speaker amplifier -
 
:Pin 3  Electret Microphone +
 
:Pin 4  Electret Microphone -
 
 
 
=PCB - Rear=
 
[[File:TCIS Connections 8.PNG]]
 
 
 
[[File:TCIS Connections 9.PNG|thumb|700px]]
 
'''J6'''  10-pin terminal for digital MEMS Microphone
 
:Pin 1  Left mic select (Vdd)
 
:Pin 2  Right mic select (GND)
 
:Pin 3  Data
 
:Pin 4  Data
 
:Pin 5  Vdd 3.3V
 
:Pin 6  Vdd 3.3V
 
:Pin 7  CLK
 
:Pin 8  CLK
 
:Pin 9  GND
 
:Pin 10  GND
 
 
 
<br style="clear:both;" />
 
 
 
=Front Board - Front=
 
[[File:TCIS Connections 10.PNG]]
 
 
 
<br style="clear:both;" />
 
 
 
=Front Board - Rear=
 
[[File:TCIS Connections 11.PNG]]
 
 
 
<br style="clear:both;" />
 
  
[[Category: Turbine]]
+
[[Category: Turbine Connections]]

Latest revision as of 14:13, 10 May 2023

AEIPS.png

Network Connection

Connect the Turbine Compact Station to the data network via the RJ45 plug. The unit supports Power over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line. If PoE is not available, the Turbine Compact Station can be powered from a 24 VDC local power supply.

Turbine Compact top view


External Connectors


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.

For more details see Turbine Compact Board Connectors