This article describes all Turbine Compact IP Standard Station connections.
+
===Network Connection===
 +
Connect the Turbine Compact Station to the data network via the RJ45 plug. The unit supports Power over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line. If PoE is not available, the Turbine Compact Station can be powered from a 24 VDC local power supply.
 +
[[File:TCIS-X top.PNG|thumb|left|250px|Turbine Compact top view]]
 +
<br style="clear:both;" />
  
The Turbine Compact IP station has a RJ-45 PoE/LAN port, and 6-pin & 10-pin external connectors.
+
=== External Connectors ===
 +
<!--[[File:TCIS Connections 1.PNG|right|250px|thumb|External Connectors on Turbine IP Station]]-->
 +
<gallery mode="traditional" widths=300px heights=300px perrow=2>
 +
File:TCIS-X rear.PNG|TCIS and TCIV
 +
File:TCIV+ rear.png|TCIV+
 +
</gallery>
 +
<br style="clear:both;" />
  
{| border="1"
+
*'''Ethernet/Power''': 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
|Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
+
*'''Secondary Power''': 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
|-
+
*'''Relays''': There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
+
*'''Input/Output''': 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.  
|-
+
*'''Audio Line Out''': A balanced 600 ohm audio line out with induction loop signal
|Relays || There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided.
 
|-
 
|Input/Output || 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.  
 
|-
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|}
 
  
'''Note!''' Use cables crimped with ferrules for terminal block connectors
+
===Input/Output Connections===
 +
There are 6 I/O connection options for the Turbine Compact Station.
 +
These connections are used as relay contacts for door lock control and external I/O devices.
  
* When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
+
For more details see [[Turbine Compact Board Connectors]]
* To make the station speak its IP address, press the call button on the station.
 
 
 
 
 
==Front Board - Front==
 
[[File:TCIS Connections 10.PNG|500px]]
 
 
 
<br style="clear:both;" />
 
 
 
==Front Board - Rear==
 
[[File:TCIS Connections 11.PNG|500px]]
 
 
 
<br style="clear:both;" />
 
  
[[Category: Turbine]]
+
[[Category: Turbine Connections]]

Latest revision as of 14:13, 10 May 2023

AEIPS.png

Network Connection

Connect the Turbine Compact Station to the data network via the RJ45 plug. The unit supports Power over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line. If PoE is not available, the Turbine Compact Station can be powered from a 24 VDC local power supply.

Turbine Compact top view


External Connectors


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.

For more details see Turbine Compact Board Connectors