Difference between revisions of "Turbine 8.0 - Release notes"
From Zenitel Wiki
(→Release info) |
(→VSF-TURBINE 8.0.3.0) |
||
Line 16: | Line 16: | ||
'''Date:''' 14.09.2023 <br> | '''Date:''' 14.09.2023 <br> | ||
'''Status:''' General Availability | '''Status:''' General Availability | ||
+ | |||
+ | =VSF-TURBINE 8.0.3.1= | ||
+ | |||
+ | ==Fixed Issues== | ||
+ | ===DS-706 Internal update, no impact on functionality.=== | ||
+ | |||
+ | <br> | ||
=VSF-TURBINE 8.0.3.0= | =VSF-TURBINE 8.0.3.0= |
Revision as of 08:01, 12 October 2023
- Previous Release - Turbine 7.5 - Release notes
This document provides the release notes for VSF-Turbine 8.0 with incremental bug fix releases. The release notes for VSF-Turbine 8.0 describe new features, improvements and issues fixed after VSF-Turbine 7.5.3.1.
Contents
- 1 Release info
- 2 VSF-TURBINE 8.0.3.1
- 3 VSF-TURBINE 8.0.3.0
- 3.1 Improvements
- 3.2 Fixed Issues
- 3.2.1 MTN-4229 HD audio for back ground music distribution in ICX-AlphaCom produced noise
- 3.2.2 MTN-4195 Negative adjustment mode is now applied
- 3.2.3 MTN-4192 Channel 1 and 2 gains are now shown in correct order
- 3.2.4 MTN-4187 Amplifier volume is now increased when volume reaches 0 dB
- 3.2.5 MTN-4181 Report DAK and Report station call events as Digital Input in ONVIF options are now working for Hanwha VMS
- 3.2.6 MTN-4176 AVC config now shown under Audio Settings
- 3.2.7 MTN-4174 On using the Handset accessory talking to an Alphacom conference the device switches back to loudspeaking after Talk Stop
- 3.2.8 MTN-4074 Fixed volume adjustment through front board keys
- 3.2.9 MTN-4072 JQuery version update to version 3.6.4
- 3.3 Known Issues
- 3.3.1 MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode
- 3.3.2 MTN-3489 Downgrading IP_LCM from vsft-6.4.3.0 will cause a reboot loop
- 3.3.3 MTN-3299 TLS Private Keys not restored on Turbine stations
- 3.3.4 MTN-2692 Turbine stations won't register to ICX500 or AlphaCom if the dash symbol is not removed from the Directory Number field.
- 3.3.5 MTN-2686 Outputs not working for Exigo amplifiers in SIP mode
- 3.3.6 MTN-2363 Factory reset does not delete uploaded Script
- 3.3.7 MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
- 3.3.8 MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
- 3.3.9 MTN-2360 Client side forwarding does not work in SIP mode
- 3.3.10 MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
- 3.3.11 MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.
- 3.3.12 MTN-2356 SNMP not working properly on TCIV under high CPU load
- 3.3.13 MTN-2339 Group call chime is not played on 3rd party SIP stations
- 3.3.14 MTN-2220 Default SNMP settings issue with firmware downgrade to 4.9
- 3.3.15 MTN-1073 Group call fails if system previously configured with ZAP
Release info
Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices:
TCIS-x, TCIV-x, TKIS-x, TMIS-x, TFIE-x, TKIE-x, TFIX-x, TFIX-x-V2, IPHDT-x, IP-LCM, ECPIR-3P, ELSIR-10CM, ELSII-10HM, ELSII-10LHM, ELSII-10LHM, ELSII-10PM, Exigo IP speakers, ENA2200, ENA2400-AC/DC, ENA2100-AC (only SIP mode and ICX AlphaCom mode), ENA2200-AC2, ENA2400-AC2 (ICX AlphaCom mode) and ENA2060-DC1 (only in SIP mode)
The firmware is delivered in two different ZIP archives and one swu file:
- vsft-8.0.x.x - Used for standard in-field upgrades
- vsft-prod-8.0.x.x - Used in production- and recovery upgrades
Version: vsft-8.0.3.1
Date: 14.09.2023
Status: General Availability
VSF-TURBINE 8.0.3.1
Fixed Issues
DS-706 Internal update, no impact on functionality.
VSF-TURBINE 8.0.3.0
Improvements
MTN-4207 AVC and DAVC upper threshold lower limit is now 60 dB
It is possible now to set upper threshold higher than 60 dB, whereas limit before was 80 dB.
MTN-2448 Support for uploading HTTPS certificates
A more user friendly approach to allow end-user to generate the CSR, and to upload HTTPS certificate to the devices.
DS-592 OpenSSL upgraded to 3.0
OpenSSL has been upgraded to the latest LTS version.
Fixed Issues
MTN-4229 HD audio for back ground music distribution in ICX-AlphaCom produced noise
Issue with PCM sampling is now fixed.
MTN-4195 Negative adjustment mode is now applied
Setting adjustment mode as a negative value in DAVC was not working on 7.5 SW. This is now fixed, both positive and negative adjustment modes can be now set and applied.
MTN-4192 Channel 1 and 2 gains are now shown in correct order
Gain values for channel 1 and channel 2 were reversed in Amplifier settings. This is now fixed, and correct gains for each channel are shown.
MTN-4187 Amplifier volume is now increased when volume reaches 0 dB
After reaching 0 dB volume, there was no sound coming from loudspeakers connected to amplifier. This is now fixed, and values higher than 0 dB produce maximal volume.
MTN-4181 Report DAK and Report station call events as Digital Input in ONVIF options are now working for Hanwha VMS
There was an issue with how Report DAK and Report station call events as Digital Input in ONVIF options were behaving in Hanwha VMS, this is now fixed and they work as expected.
MTN-4176 AVC config now shown under Audio Settings
AVC config was missing on 7.5 version. This is fixed, AVC is now visible and configurable.
MTN-4174 On using the Handset accessory talking to an Alphacom conference the device switches back to loudspeaking after Talk Stop
On normal calls the default behaviour is to switch back to loudspeaking after the call ends, but when talking into a simplex conference the conference audio is now restored on the last used audio accessory (handset).
MTN-4074 Fixed volume adjustment through front board keys
The volume of the TFIE-6 is now updated when using front board keys both in the display and web.
MTN-4072 JQuery version update to version 3.6.4
Now the Station Web is running newer JQuery version with included JQuery migrate to support some of the older functions.
Known Issues
MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode
IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored
MTN-3489 Downgrading IP_LCM from vsft-6.4.3.0 will cause a reboot loop
If downgrading the IP_LCM from vsft-6.4.3.0 to an earlier version, the IP_LCM will go into a reboot loop. Workaround is to factory reset the IP_LCM just after downgrading.
MTN-3299 TLS Private Keys not restored on Turbine stations
In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.
MTN-2692 Turbine stations won't register to ICX500 or AlphaCom if the dash symbol is not removed from the Directory Number field.
In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.
MTN-2686 Outputs not working for Exigo amplifiers in SIP mode
GPO's does not work when exigo amplifiers are in SIP mode.
MTN-2363 Factory reset does not delete uploaded Script
All uploaded scripts should also be removed on Factory reset
MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
MTN-2360 Client side forwarding does not work in SIP mode
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
MTN-2356 SNMP not working properly on TCIV under high CPU load
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
MTN-2339 Group call chime is not played on 3rd party SIP stations
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
MTN-2220 Default SNMP settings issue with firmware downgrade to 4.9
When downgrading from VSFT 4.11+ to 4.9 a factory reset is necessary if user wants to use default SNMP configuration. For custom snmp.conf file, re-upload with a custom snmp.conf file will fix the problem.
MTN-1073 Group call fails if system previously configured with ZAP
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.