Actions

Difference between revisions of "AlphaCom XE1"

From Zenitel Wiki

(Serial Ports)
(Connections)
Line 17: Line 17:
 
* There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
 
* There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
 
* The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
 
* The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
 +
 +
[[File:XEsmallConnections.png|thumb|left|500px|XE1 IP and serial connections]]
 +
<br style="clear:both;" />
  
 
====Serial Ports====
 
====Serial Ports====

Revision as of 16:22, 3 November 2016

AlphaCom XE1 Audio Server with HD Voice

Highlights

  • Made to provide critical communication in any environment
  • Supports 552 IP stations
  • Environmental friendly and energy saving - max. 4 W
  • SIM card based software configuration and disaster recovery
  • Fully compatible with any AlphaCom system

Additional Documentation on Zenitel.com

Connections


  • The exchange is normally powered from the mains via a 5 VDC power supply
  • Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
  • There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
  • The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
XE1 IP and serial connections


Serial Ports

Serial Port 0 - 9-Pin D-sub (RS232 Only)

No additional settings necessary

Serial Port 1 - RJ45 (RS232/422/485)

Additional settings:
RS232:
RS422/485:
  • Switch 8 on S601 on the AMC-IP board must be set to ON.
  • Take off the top lid to reach the jumpers inside, and set them to the correct position.
- RS485: Both jumpers in position 2-3 (default)
- RS422: Both jumpers in position 1-2
RS422/485 selector for Serial Port 1 in the XE1