<br> | <br> | ||
* ''Remote door opening''. <br> AlphaCom E will generate a DTMF signal when a button is pressed in the AlphaCom station during conversation with the CB901 door station. This signal will be decoded by the remote output board DP997 inside the RM door station and used to activate the magnetic lock. | * ''Remote door opening''. <br> AlphaCom E will generate a DTMF signal when a button is pressed in the AlphaCom station during conversation with the CB901 door station. This signal will be decoded by the remote output board DP997 inside the RM door station and used to activate the magnetic lock. | ||
+ | |||
+ | |||
+ | |||
+ | === Software Description === | ||
+ | ====Ring-Master CB901 ==== | ||
+ | |||
+ | The ETP (External Trunk Protocol) communication software is included in revisions from TX5.7. The software in the Ring-Master system must be upgraded if the present software revision is TX5.6 or lower. | ||
+ | |||
+ | The upgrade includes changing of E-PROMs on all processor boards. It is not necessary to change the software in the DNC. | ||
+ | |||
+ | If the software revision is lower than TX5.0 (TX4.x or TX3.x) the processor board(s) must be changed. | ||
+ | |||
+ | Connector P2 must be present on the motherboard in board position 19 in order to get power to the serial links of the processor board NFE1683. | ||
+ | |||
+ | Old systems using the first processor boards NFE1515 and NFE1592 does not have connector P2 on the motherboard in position 19. The new processor board NFE1683 can then be installed in position 20 if there are long pins on the back for the PC port connections. If there are no connection pins at the back, the whole cabinet must be changed to type DP979. |
Revision as of 09:28, 28 July 2008
Contents
SYSTEM BUILD-UP
General Description
An existing Ring-Master CB901 system can be expanded by adding one or more STENTOFON AlphaCom E exchanges. The two systems are interconnected via data and audio links. Stations and equipment in both systems will interact as part of the same system. The AlphaCom E IP services can be accessed from the Ring-Master system.
Data
Data are transmitted via one or two serial RS232 links.
- One link (ETP, External Trunk Protocol) is used for station-tostation
calls, Group Call, Call Request and Caller ID.
- An optional link (SIO, Serial Input Output) is used for other
functions like Privacy information and Call Request camp on.
Audio
The audio interconnection between CB901 and AlphaCom E is
analogue.
- There are 6 conversation channels in a 12 pair twisted cable
between each Interlink B board in CB901 and AGA board(s) in
AlphaCom E.
Audio switching control (Duplex)
There is no transfer of switching control signals between the CB901 and
AlphaCom E. The switching will take place individually in the Ring-Master station and in AlphaCom E.
Programming
The CB901-AlphaCom E interface features are programmed by use of:
- SVT for the CB901 part
- AlphaPro and AlphaWeb for the AlphaCom E part and the Ring-Master Daemon
Basic System Features
All internal features in both systems will remain as they are.
The following features will be included in the interface between CB901 and AlphaCom E:
- Station to station calling.
- Display information.
Call number of calling station or station ID
- Simultaneous (global) All-Call and Group-Call.
One global call at the time in the RM /ACE system.
- Call request and queuing from stations in CB901 to master stations(guards) in AlphaCom E.
Calling stations will be camped on in one program distribution channel in CB901.
- Pocket paging.
Automatic pocket paging in both systems. One individual serial ESPA 4.4.4. connection between AlphaCom E and the pager system; and CB901 and the pager system.
The info in the pager display will identify the caller who has to be called back manually.
- Privacy.
Stations in CB901 will be tested for privacy also when called from AlphaCom E. The subscriber board must be modified according to section 6.2
- Remote door opening.
AlphaCom E will generate a DTMF signal when a button is pressed in the AlphaCom station during conversation with the CB901 door station. This signal will be decoded by the remote output board DP997 inside the RM door station and used to activate the magnetic lock.
Software Description
Ring-Master CB901
The ETP (External Trunk Protocol) communication software is included in revisions from TX5.7. The software in the Ring-Master system must be upgraded if the present software revision is TX5.6 or lower.
The upgrade includes changing of E-PROMs on all processor boards. It is not necessary to change the software in the DNC.
If the software revision is lower than TX5.0 (TX4.x or TX3.x) the processor board(s) must be changed.
Connector P2 must be present on the motherboard in board position 19 in order to get power to the serial links of the processor board NFE1683.
Old systems using the first processor boards NFE1515 and NFE1592 does not have connector P2 on the motherboard in position 19. The new processor board NFE1683 can then be installed in position 20 if there are long pins on the back for the PC port connections. If there are no connection pins at the back, the whole cabinet must be changed to type DP979.