Actions

Difference between revisions of "TCIx Connections"

From Zenitel Wiki

Line 14: Line 14:
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|}
 
|}
 +
 +
 +
*'''Ethernet/Power''': 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
 +
*'''Secondary Power''': 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
 +
*'''Relays''': There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
 +
*'''Input/Output''': 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
 +
*'''Audio Line Out''': A balanced 600 ohm audio line out with induction loop signal
  
 
  '''Note!''' Use cables crimped with ferrules for terminal block connectors
 
  '''Note!''' Use cables crimped with ferrules for terminal block connectors

Revision as of 16:57, 6 January 2017

TCIS Connections
TCIS-X rear.PNG


Ethernet/Power 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
Secondary Power 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
Relays There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
Input/Output 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
Audio Line Out A balanced 600 ohm audio line out with induction loop signal


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal
Note! Use cables crimped with ferrules for terminal block connectors
  • When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
  • To make the station speak its IP address, press the call button on the station.

Power Supply

The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.

Network Connection

Turbine Compact top view


There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.

For more details see Turbine Compact Board Connectors