Difference between revisions of "TCIx Connections"
From Zenitel Wiki
Line 1: | Line 1: | ||
{{APS}} | {{APS}} | ||
+ | ===Network Connection=== | ||
+ | Connect your Intercom station to the data network | ||
+ | [[File:TCIS-X top.PNG|thumb|left|250px|Turbine Compact top view]] | ||
+ | <br style="clear:both;" /> | ||
+ | There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection. | ||
+ | |||
=== External Connectors === | === External Connectors === | ||
[[File:TCIS Connections 1.PNG|right|350px|thumb|External Connectors on Turbine IP Station]] | [[File:TCIS Connections 1.PNG|right|350px|thumb|External Connectors on Turbine IP Station]] | ||
Line 15: | Line 21: | ||
If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply. | If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
===Input/Output Connections=== | ===Input/Output Connections=== |
Revision as of 17:46, 13 March 2017
Network Connection
Connect your Intercom station to the data network
There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.
External Connectors
- Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
- Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
- Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
- Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
- Audio Line Out: A balanced 600 ohm audio line out with induction loop signal
Power Supply
The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.
Input/Output Connections
There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.
For more details see Turbine Compact Board Connectors