Difference between revisions of "Mirasys"
From Zenitel Wiki
m |
|||
Line 1: | Line 1: | ||
− | {{ | + | {{AI}} |
==Introduction== | ==Introduction== | ||
− | The | + | The Mirasys VMS can be integrated with the ICX system or the AlphaCom system. The integration is based on EDO and event handler programming in the ICX/AlphaCom. |
==AlphaCom programming== | ==AlphaCom programming== |
Revision as of 12:54, 19 November 2019
Contents
Introduction
The Mirasys VMS can be integrated with the ICX system or the AlphaCom system. The integration is based on EDO and event handler programming in the ICX/AlphaCom.
AlphaCom programming
UDP
Assign a UDP flag to all intercom stations with a camera, For instance:
- UDP 1
- UDP text: Mirasys camera
Assign a UDP flag to all operator intercom stations, For instance:
- UDP 2
- UDP text: Mirasys operator
EDO port
Communication is based on EDO. Program an EDO port, for instance EDIO 1 as following:
- Port Type: TCP/IP client
- IP-address: The IP-address of the Mirasys server
- Port: 40000
- Keep Alive - Enabled
EDO events
The events below are examples, please modify/add as appropriate.
Conversation event - Outgoing
This event can be used to indicate to victor that 2 stations are connected in a conversation, or that the conversation has ended:
- Owner Type: stations With UDP: 1
- Event type: 8 - Conversation-Outgoing
- When Change To: ON or OFF
- When Related To: Stations With UDP 2 - In an AlphaNet set Node to 255
- Action Command: EDO 1 "Cam %1d %chg(ON,OFF)"
Conversation event - Incoming
This event can be used to indicate to victor that 2 stations are connected in a conversation, or that the conversation has ended:
- Owner Type: stations With UDP: 1
- Event type: 7 - Conversation-Incoming
- When Change To: ON or OFF
- When Related To: Stations With UDP 2 - In an AlphaNet set Node to 255
- Action Command: EDO 1 "Cam %1d %chg(ON,OFF)"
Mirasys setup
Mirasys license
The Mirasys VMS must have the license 'UniversalDataDriver' in place.
Mirasys setup
The Mirasys interface is programmed by including the file 'UDD4ZenitelAlpha.xml' in the directory 'program files/DVMS/DVR folder'. The contents of this file is project specific, as all directory numbers of intercom stations with a camera must be defined in this file. Please open the downloaded file in an ASCII text editor and put the appropriate directory numbers in the section 'array name="p1" params="EDOMessageParams"'.
Vingtor-Stentofon cameras
Video streams from the Vingtor-Stentofon cameras (CP-CAM and TCIV) can be accessed by Mirasys. For licensing of the required 'HTTPIPcapture-driver', please contact your Mirasys distributor.
TCIV
Settings for the TCIV camera in Mirasys are:
- http://IP_ADDRESS:8090/mjpg/video.mjpg
- fps: ~10 fps
- Codec: JPEG
CP-CAM
Settings for the CP-CAM camera in Mirasys are:
- http://IP_ADDRESS/mjpg/video.mjpg
- fps: ~10 fps
- Codec: JPEG
Sending commands from Mirasys to AlphaCom
It is also possible to send commands to AlphaCom, for instance to start a voice message to an IP-speaker when a specific button on the Mirasys GUI is clicked.
Mirasys license
For this functionality the Mirasys VMS must have the license 'UniversalOutputDriver' in place.
AlphaCom
Program an event and event trigger to send the alarm message to the correct IP-speaker. For instance event trigger directory number 9595.
Mirasys
Mirasys uses the custom scripting capability of the AlphaCom. Program Mirasys to send the following http-command:
In this case it appears that the station with directory number 110 (operator station associated with the Mirasys GUI) has dialed 9595, which in turn triggers the specified event.