Difference between revisions of "TCIx Connections"
From Zenitel Wiki
Line 2: | Line 2: | ||
[[File:TCIS-X rear.PNG|left|350px]] | [[File:TCIS-X rear.PNG|left|350px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
*'''Ethernet/Power''': 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line. | *'''Ethernet/Power''': 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line. |
Revision as of 16:58, 6 January 2017
- Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
- Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
- Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
- Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
- Audio Line Out: A balanced 600 ohm audio line out with induction loop signal
Note! Use cables crimped with ferrules for terminal block connectors
- When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
- To make the station speak its IP address, press the call button on the station.
Power Supply
The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.
Network Connection
There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.
Input/Output Connections
There are 6 I/O connection options for the Turbine Compact Station. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
For more details see Turbine Compact Board Connectors