Actions

Difference between revisions of "Turbine 4.9 - Release notes"

From Zenitel Wiki

(Bugfixes and Improvements 4.7.3.1)
(Bugfixes and Improvements 4.7.2.4 (LA))
Line 65: Line 65:
 
===VSIS-1230 TCIV limitations with PAS and MJPG clients===
 
===VSIS-1230 TCIV limitations with PAS and MJPG clients===
 
Available number of Permanent Audio Streams on TCIV has been decreased to 1. If PAS is enabled on TCIV, number of available MJPG clients will be decreased by 1 as long as PAS is enabled. This means that limitations are 1 MJPG client for 480P, and 2 MJPG clients for 240P.
 
Available number of Permanent Audio Streams on TCIV has been decreased to 1. If PAS is enabled on TCIV, number of available MJPG clients will be decreased by 1 as long as PAS is enabled. This means that limitations are 1 MJPG client for 480P, and 2 MJPG clients for 240P.
 
== Bugfixes and Improvements 4.7.2.4 (LA) ==
 
===MTN-696 Selectable group call chime in Pulse===
 
In order to use the group call functionality for broadcasting messages through PTT the chime must be possible to deactivate or disabled during such an announcement
 
 
===MTN-845 Turbine with Static IP failed to upgrade from different subnet===
 
When Turbine is set with static IP address the upgrade will fail when IMT or TFTP server is located in different LAN subnet. This is now fixed with proper gateway handling in barebox (bootloader) environment. NOTE: Upgrading the bootloader is done from the Station web page, "Station Administration" > "Manual Upgrade", enter Image file: '''boot/sti-4.7.2.4''' ("boot/" being a prefix in front of the file name).
 
 
===MTN-890 VAD control from AlphaCom through $DIP doesn't work on Turbine===
 
Fixed
 
 
===MTN-918 "Line out source: Microphone" setting does not work, option is missing in SIP/Pulse===
 
Fixed
 
 
===MTN-1049 Relay idle setting doesn't take effect immediately===
 
Changed Idle relay setting is now applied right away.
 
 
===MTN-1061 Web call on Turbine should also handle Incoming/Ringing call===
 
Web call now supports answering call, and reports call status correctly.
 
 
===MTN-1107 802.1x certificate does not survive a software upgrade===
 
Previously uploaded security certificate is being removed with firmware upgrade. For station to successfully authenticate toward 802.1x AAA server, the certificate will need to be uploaded again.
 
 
===MTN-1165 Wrong MAC shown after loading XML backup on Turbine===
 
Fixed for Turbine. MAC address, host name, hardware type and frontboard (if factory set in /goform/zForm_fact_set) will be correctly set after restore of config file.
 
 
===MTN-1196 TCIV rebooting when connected to CCTV server===
 
Implemented solution to prevent more then 4 client connections for MJPEG stream 240p and more then 2 for 480p.
 
 
===MTN-1230 Multicast for Turbine Stations with onboard switch (TFIE, TKIE and ECPIR) fails===
 
Repaired multicast handling in networks that do not have an IGMP querier.
 
 
===VSIS-318 License grace period expiration warning on StationWeb===
 
Warning is displayed on station web under server monitoring and licensing. Remaining days of grace period are displayed.
 
 
===VSIS-704 Group call should use caller codec===
 
Only the g722 codec was supported before, so now the call codec is taken from caller
 
 
===VSIS-749 TCIV in reboot loop when camera module upgrade takes > 1min===
 
If camera module upgrade took longer than 1 minute, TCIV station ended up in reboot loop. This is now fixed.
 
 
===VSIS-819 Hide unsupported DAK functions on substations===
 
DAK functions which are not supported on substations are no longer shown.
 
 
===VSIS-1158 TMIS Factory Reset from Frontboard===
 
Key scanner chip was reset after factory reset key press detection
 
 
===VSIS-1162 Disable Call functions on DAKs when Idle function does not support it===
 
Certain Idle functions do not allow Call function to be set on DAK. For those functions, Call functions are now disabled in station web.
 
 
===VSIS-1163 Turbine in SIP/Pulse mode does not read ipaddress if DAK is set to call ringlist===
 
The turbine station will now read ipaddress if the station is not registered and the ringlist is not a direct ip call (configured to call number@ipaddress).
 
 
===VSIS-1165 Added Video setup mode - Cisco===
 
Cisco phones have issue when sending less then 25 fps. Now users can select Cisco mode on StationWeb and video will always be sent in 25 fps. In that case fps parameter on StationWeb  will just be related to how many images will be different
 
 
===VSIS-1172 ECPIR-3P DAK LED notification has been improved===
 
See documentation for more details
 
 
===VSIS-1173 TCIV Video is now enabled by default===
 
Mode is MJPEG with 480p and 15fps.
 
  
 
==Security and Improvements 4.7.2.4==
 
==Security and Improvements 4.7.2.4==

Revision as of 12:04, 20 March 2018

Contents

VSF-Turbine 4.9

Release info

Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for all Turbine Family Intercom stations including devices: TCIS-x, TKIS-2, TCIV-x, TMIS-x, TFIE-x, TKIE-x, TFIX-x, ECPIR-3P and Exigo IP speakers.. The firmware is delivered in two different ZIP archives:

  • sti-4.9.3.x - Used for standard in-field upgrades
  • sti-prod-4.9.3.x - Used in production and recovery upgrades

Version: 4.9.2.2
Date: 20.03.2018
Status: Limited Availability

New Features 4.9

SNOW-103 Exigo Network Amplifiers can be connected to Alphacom

  • ENA2100-AC, ENA2200, ENA2400-AC, ENA2400-DC can be connected directly to AlphaCom
  • Each amplifier channel will behave as an IP station with all features available
  • Monitoring of the amplifiers available via the Alphacom event handler and syslog
  • Function requires AlphaSys version 12.5.2.0 or later

SNOW-250 Advanced Turbine AVC settings on StationWeb

Exposed advanced AVC settings like thresholds, attack and decay rates, lockout time, etc. on Turbine StationWeb for AVC algorithm parametrization. These options should be used only in case when default AVC behavior needs to be fine tuned and when technician has good understanding about the AVC technology.

SNOW-87 Virtual I/O script on DAK event with reading GPI status

Now we can enable/disable DAK key action (e.g. make call) according to state change on certain GPI. Use case: disable intercom for non-authorized personnel using badge-reader, deny intercom call without vehicle in front of the station (detected by a loop into the floor)

Technical Preview

VSIS-865 Digital Audio Squelch on Far-End audio

New function for silencing audio to be played to speaker, if signal energy is below a configurable threshold level. This can be used to suppress noise when below-desired-level signal is present.

SNOW-229 Secure SIP and Secure RTP for Turbines in SIP mode

Added support on Turbines for SIP over TLS. SIP over TLS encrypts the transport layer using the same method as HTTPS which uses certificates to validate the server. In addition, the Turbines now support SRTP which brings encryption to RTP media (call audio). This means that now both call metadata and call media can be fully encrypted. Note: TCIV H.264 is not supported with SRTP

SNOW-191 Support SIP Early Media during 180-Ringing or 183-Session Progress

Support playing a media during SIP 180-Ringing or SIP 183 Call progress, instead of a locally generated ringing tone. This is a very common setup in iPBX systems where server shall generate a media to be played during session progress and before call is accepted (e.g. Call queued before answered). Note that we do not fully support RFC3960.

Bugfixes and Improvements 4.7.3.2 (GA)

MTN-1419 Turbine sends 5 identical SIP Register messages towards iPBX

This can potentially cause issues (e.g. SPAM filtering) on Alcatel OXE 12.0 or latest Asterisk. Improvement implemented.

MTN-1737 Turbine can have registration issues when using TCP Outbound transport

If there was an unsuccessful registration with 3rd party iPBX when using TCP Outbound transport type, the Turbine would not be able to re-register without a reboot. This is now fixed.

MTN-1739 Turbine stations configured with SIP TLS may start replying to wrong port (5060)

If the record-route header did not specify a port or sips scheme, port 5060 was used to send requests while the record-route indicated transport type TLS which should default to port 5061.

MTN-1666 Periodic sound loss when doing announcements using relayed multicast

Improved the Relayed Multicast handling to be more robust on larger systems.

Bugfixes and Improvements 4.7.3.0 (GA)

VSIS-1146 Turbine and INCA fail in AlphaCom with Relay Multicast

Multicast fails when Turbine and INCA listen to audio program over Relayed Subnet (AlphaCom environment)

VSIS-1222 Internet Explorer had issues with properly handling dynamic UI controls

Introduced better javascript handling so that all HTML components are properly rendered in IE

VSIS-1196 Answer Group Call doesn't work with Answer Call function

When Answer Group Call is used with Answer/End Call action it works OK (workaround).

VSIS-1211 Multiple MJPG streams in browser causes poor TCIV audio quality

With multiple MJPG streams open in different browsers, we can have poor audio quality because the CPU is very high. Fixed with limiting number of 240p streams to 3 (from 4).

VSIS-1230 TCIV limitations with PAS and MJPG clients

Available number of Permanent Audio Streams on TCIV has been decreased to 1. If PAS is enabled on TCIV, number of available MJPG clients will be decreased by 1 as long as PAS is enabled. This means that limitations are 1 MJPG client for 480P, and 2 MJPG clients for 240P.

Security and Improvements 4.7.2.4

VSIS-840 Security issue: SSL Certificate Weak Public Key Strength on Turbine/INCA

Security scanner detected that SSL certificates are using weak public key strength. Key length has been increased to 2048.

VSIS-841 Security issue: SSL Weak Protocol Version Supported on Turbine/INCA

Security scanner detected support for old versions of SSL. There are now disabled.

VSIS-842 Security issue: SSLv3 Fallback Vulnerability (POODLE) on Turbine/INCA

Security scanner detected SSLv3 Fallback Vulnerability (POODLE). This is now fixed.

VSIS-882 Security issue: SSL 64-bit Block Size Cipher Suites Supported (SWEET32)

Security scanner detected support for weak 64-bit block size ciphers that could be compromised. Those are now disabled in the system.

Known Issues 4.7.3.0

MTN-268 Relay follow M-key cannot handle quick M

Relay configured to follow M-key does not handle quick press on M-key

MTN-323 Noise from wind on TCIS

Wind may cause powerful acoustic signal on mic that software is not able to filter and at same time keep clear voice. Workaround is to make mechanical filtering or shielding of wind effect on mic.

MTN-408 802.1X config not properly handling special characters in password

Character like % is not handled in the password input field for 802.1x.

MTN-552 PULSE: (Re)Registration of SIP phones takes a long time

Long (re)registration times observed on Divus SIP client and SNOM phone. If the same SIP phone is registered against AlphaCom the process is almost instantaneous.

MTN-598 INCA station fails to register if Hebrew name is too long

More than 12 characters entered causes registration problems

VSIS-878 Factory reset does not delete uploaded Script

All uploaded scripts should also be removed on Factory reset

MTN-1073 Group call fails if system previously configured with ZAP

If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.

MTN-1077 Lamp test not functioning on ECPIR-3P and belonging EBMDR-8

Alphacom DAK Lamp test (feature 7874) not implemented on DAK Panel ECPIR-3P and belonging EBMDR-8

VSIS-1202 TFIE-6 does not display AlphaCom status-messages in Idle

There is no way of knowing if a TFIE-6 is for example forwarded(71,72) or marked absent(77x). Workaround: During commissioning it is possible by Class Of Service programming in AlphaCom to deny access to these services for the TFIE-6

VSIS-1207 Turbine Tone test requires restart to enable it after being disabled

Turbine tone test is disabled by default. If it is enabled and later on disabled, it will require station reboot to enable tone test again. Workaround: Tone test started to work again after rebooting the station.

VSIS-1214 Turbine sends UDP SIP even though configured to use TCP

Turbine sends UDP SIP even though configured to use TCP. Workaround: configure Outbound Proxy to have the same value as Server Domain.