Actions

TKIE Dimensions & Mounting Instructions

From Zenitel Wiki

Revision as of 12:58, 17 October 2016 by Roarl (talk) (Opening the enclosure)
  Dimensions (WxHxD) Weight
TKIE-1 65 x 100 x 25 mm 0.1 kg
TKIE-2 74 x 106 x 30 mm 0.2 kg


TFIE/TFIX Extended Station Dimensions

TFIE Extended Station - Front view



Mounting the unit

Preparation for Drilling

The four mounting holes in the onwall box are Ø6.4 mm. Distance: 298 x 130 mm. Size of hole to be drilled depends on whether it is wall or column mounting:

TFIE Mounting 1.PNG


Location

Make sure there is a clearance of minimum 230 mm on the left for frame movement.

TFIE Mounting 2.PNG


Mounting Plate or Column

Fix the unit to mounting plate or column with 4 screws that fit the 4 screw holes in each corner of on-wall box (6.4 mm diameter). Use M5 x 20 or 25 with Philips head DIN7985 or Torx. Head diameter: 10 mm.

TFIE Mounting 3.PNG


Wall

Fix the unit to the wall with 4 screws that fit the 4 screw holes in each corner of the on-wall box (6.4 mm diameter). Use Panhead – DIN7981 screw for plug or wooden wall. Head diameter: 10.8 B5.5 x 38 or 45 mm.

TFIE Mounting 4.PNG


Mounting Cable Gland

Remove two blind plugs and insert one M16 and one M20 cable glands. Make sure to tighten sufficiently to attain IP66 rating for watertightness but be aware of plastic material limitations.

TFIE Mounting 5.PNG


In order to ensure the required minimum degree of protection, the cable glands must be tightened securely.
Over-tightening can impair the degree of protection and damage the unit.
When tightening the cap nut of a cable gland, a suitable tool shall be used to prevent the gland from twisting.

Fastening Front Frame

Do NOT use more than 2.5 Nm torque when fastening the 12 screws into the front frame.

TFIE Mounting 6.PNG