The Turbine range of stations have configurable I/O's, i.e. you can choose if an I/O should be used as an Input or as an Output. By default all I/O's are set as Inputs.

By default an input is triggered by a closing contact (referred to as "NO - Normally Open"). The input can be configured as "Input NC" (NC - Normally Closed) instead. (Requires firmware 8.1.3.0 or later).

Enable Advanced Configuration mode, and select Edge Configuration > I/O from the menu

I/O settings web page


For each of the six I/O pins the options are:

  • Input (default)
  • Input NC
  • Output


Use Inputs As Key Matrix

If there is a need for more than the 6 inputs available, it is possible to use the Use Inputs As Key Matrix and combine inputs as in a diode matrix, and in this way create more DAKs. By for example using 3 inputs it is possible to get 7 DAKs.

The different options are:

  • 2 Inputs (input 1-2, DAK 1-3)
Input 2 Input 1 DAK key triggered
0 1 DAK1
1 0 DAK2
1 1 DAK3
0 0 Last DAK released


  • 3 Inputs (input 1-3, DAK 1-7):
Diode matrix when using 3 inputs to activate 7 DAK keys
Input 3 Input 2 Input 1 DAK key triggered
0 0 1 DAK1
0 1 0 DAK2
0 1 1 DAK3
1 0 0 DAK4
1 0 1 DAK5
1 1 0 DAK6
1 1 1 DAK7
0 0 0 Last DAK released


  • 4 Inputs (input 1-4, DAK 1-15):
Input 4 Input 3 Input 2 Input 1 DAK key triggered
0 0 0 1 DAK1
0 0 1 0 DAK2
0 0 1 1 DAK3
0 1 0 0 DAK4
0 1 0 1 DAK5
0 1 1 0 DAK6
0 1 1 1 DAK7
1 0 0 0 DAK8
1 0 0 1 DAK9
1 0 1 0 DAK10
1 0 1 1 DAK11
1 1 0 0 DAK12
1 1 0 1 DAK13
1 1 1 0 DAK14
1 1 1 1 DAK15
0 0 0 0 Last DAK released

The DAK actions are configured from Direct Access Key Settings.