Introduction

The interface between AlphaCom and the Mirasys VMS, is based on EDO and event handler programming in the AlphaCom.

AlphaCom programming

UDP

Assign a UDP flag to all intercom stations with a camera, For instance:

  • UDP 1
  • UDP text: Mirasys camera

Assign a UDP flag to all operator intercom stations, For instance:

  • UDP 2
  • UDP text: Mirasys operator

EDO port

Communication is based on EDO. Program an EDO port, for instance EDIO 1 as following:

  • Port Type: TCP/IP client
  • IP-address: The IP-address of the Mirasys server
  • Port: 40000
  • Keep Alive - Enabled

EDO events

The events below are examples, please modify/add as appropriate.

Conversation event - Outgoing

This event can be used to indicate to victor that 2 stations are connected in a conversation, or that the conversation has ended:

  • Owner Type: stations With UDP: 1
  • Event type: 8 - Conversation-Outgoing
  • When Change To: ON or OFF
  • When Related To: Stations With UDP 2 - In an AlphaNet set Node to 255
  • Action Command: EDO 1 "Cam %1d %chg(ON,OFF)"

Conversation event - Incoming

This event can be used to indicate to victor that 2 stations are connected in a conversation, or that the conversation has ended:

  • Owner Type: stations With UDP: 1
  • Event type: 7 - Conversation-Incoming
  • When Change To: ON or OFF
  • When Related To: Stations With UDP 2 - In an AlphaNet set Node to 255
  • Action Command: EDO 1 "Cam %1d %chg(ON,OFF)"

Mirasys setup

Mirasys license

The Mirasys VMS must have the license 'UniversalDataDriver' in place.

Mirasys setup

The Mirasys interface is programmed by including the file 'UDD4ZenitelAlpha.xml' in the directory 'program files/DVMS/DVR folder'. The contents of this file is project specific, as all directory numbers of intercom stations with a camera must be defined in this file. Please open the downloaded file in an ASCII text editor and put the appropriate directory numbers in the section 'array name="p1" params="EDOMessageParams"'.

Vingtor-Stentofon cameras

Video streams from the Vingtor-Stentofon cameras (CP-CAM and TCIV) can be accessed by Mirasys. For licensing of the required 'HTTPIPcapture-driver', please contact your Mirasys distributor.

TCIV

Settings for the TCIV camera in Mirasys are:

CP-CAM