ATEX Substation - 1007095300
From Zenitel Wiki
Features
- Heavy duty industrial ATEX substation
- Designed for the STENTOFON AlphaCom exchange
- Can make calls and call request to pre-programmed stations
- Robust buttons for:
- - Call request
- - Press to talk for optional simplex conversation
- - Cancel
- Rugged weatherproof cabinet of lacquered steel
- Handset for soft speaking conversation
- Requires an external loudspeaker
- Relay output for control of optional signal unit
- Advanced supervision functions
Description
The station is designed to satisfy ATEX regulations and carries the following approval EX de [ia] II C T6.
Power is needed for the internal 10 W amplifier to drive an 8 Ohm or 20 Ohm speaker. The station is connected to the exchange using a 3-pair cable.
The handset microphone is always connected, thereby permitting direct answer back when receiving a call.When using the handset during conversation, the external loudspeaker is turned off.
An optionally connected call warning device will also turn off when lifting the handset for conversation. The conversation will be cancelled by placing the handset back on hook, or by pressing the “Cancel” button. The call request button can be programmed to call any number in the exchange.
The station is made for duplex conversations but can be put in simplex mode by pressing the M button in the station, or the talk button in the handset.
To provide maximum availability the station comes with advanced supervision functions. The station line test will detect if there are any faults in the network or station electronics. In addition the station supports tone test, testing the complete transmission path including microphone and speaker. The status of the stations is reported to AlphaWeb as well as to 3rd party management systems using SNMP, Syslog, OP C or the STENTOFON Software Development Kit (SDK).
Specifications
Dimensions (WxHxD) | 215 x 687 x 187 mm |
Protection | EX de [ia] IIC T6 |
IP Protection | Cabinet IP-65 |
Handset | Intrinsically safe, via zener barriers inside the EXd enclosure |
Weight |
23 kg |
Temperature | -40°C to +55°C |
Relative Humidity | 0% to 95% |
Internal Power Amplifier | 10 W |
Power amp operating voltage | 24-30 VDC |
Loudspeaker | External 8 or 20 ohms loudspeaker must be installed |
Material | Cabinet in laquered stel, light beige |
Keypad | 3 large buttons: M, DAK, C |
Cable requirement | 2 pairs for audio plus 1 pair for 24-30 VDC to power amplifier |
Max loudspeaker output |
5 W with 20 ohms loudspeaker 10 W with 8 ohms loudspeaker |
Distance to exchange for audio |
4.0 km (18 AWG - 0.9 mm) 3.4 km (20 AWG - 0.8 mm) 2.0 km (22 AWG - 0.6 mm) |
Distance to power supply |
8 ohms loudspeaker, 24 VDC: 0.6 mm: 70 m 0.8 mm: 100 m 1 mm: 200 m 8 ohms loudspeaker, 30 VDC: 0.6 mm: 150 m 0.8 mm: 250 m 1 mm: 450 m 20 ohms loudspeaker, 24 VDC: 0.6 mm: 150 m 0.8 mm: 250 m 1 mm: 400 m 20 ohms loudspeaker, 30 VDC: 0.6 mm: 350 m 0.8 mm: 650 m 1 mm: 1000 m |
Control of external call device | Potential free relay contact (3A, 30 VDC) |
Connector type | Screw terminals |
Compliance | CE, FCC Part 15 |