Actions

TCIx Connections

From Zenitel Wiki

Revision as of 08:49, 12 October 2016 by Roarl (talk) (Input Connectors)
TCIS Connections 1.PNG

This article describes all Turbine Compact IP Standard Station connections.

The Turbine Compact IP station has a RJ-45 PoE/LAN port, and 6-pin & 10-pin external connectors.

Ethernet/Power 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
Secondary Power 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
Relays There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided.
Input/Output 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.
Audio Line Out A balanced 600 ohm audio line out with induction loop signal
Note! Use cables crimped with ferrules for terminal block connectors
  • When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
  • To make the station speak its IP address, press the call button on the station.


Output Connectors + 1 relay

Connecting to the onboard relay. Extra LED controlled by output 1

The extra relay for any of the 6 I/O pins is connected as shown:

TurbineCompactOutputs.PNG

Most general purpose P-Channel MOSFET's should work. Recommended example: BSS84

The 5,3V output can deliver 200mA current maximum

PCB - Rear

TCIS Connections 8.PNG


J6 10-pin terminal for digital MEMS Microphone

TCIS Connections 9.PNG
Pin 1 Left mic select (Vdd)
Pin 2 Right mic select (GND)
Pin 3 Data
Pin 4 Data
Pin 5 Vdd 3.3V
Pin 6 Vdd 3.3V
Pin 7 CLK
Pin 8 CLK
Pin 9 GND
Pin 10 GND


Front Board - Front

TCIS Connections 10.PNG


Front Board - Rear