Actions

TCIx Connections

From Zenitel Wiki

Revision as of 17:49, 13 March 2017 by Asle (talk)
APS.png

Network Connection

Connect the Intercom station to the data network via the RJ45 plug. The unit supports Powerr over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line.

Turbine Compact top view



External Connectors

External Connectors on Turbine IP Station
TCIS-X rear.PNG


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal

Power Supply

The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.

For more details see Turbine Compact Board Connectors