Actions

PROGRAM

From Zenitel Wiki

Revision as of 09:17, 2 August 2017 by Roarl (talk)
AlphaCom icon 300px.png
PROGRAM 0x0001 1 AMC 05.00
$PROG L101 L801 U1

$PROG L101 LV

Set Audio Program for single station or a predefined group of stations.
1 NET_OBJ_REF{ECL_STATION, ECL_ST_GROUP} A - user or station.
2 NET_OBJ_REF{ECL_PROGRAM} Audio program

- Null value or directory number for “program off” disconnects any active program(s).

3 UINT1 Priority

1 = Low

2 = Medium (default)

3 = High

4 = Alarm

Response: PROGRAM_ACK, PROGRAM_NAK

Back to AlphaNet message list