Activate RCO output at remote station feature
From Zenitel Wiki
58 FEAT_PULSE_PEER_RCO
Param1 | Description |
---|---|
?? | Activate Remote Control output at peer station |
During connection: Generates event "Door Opening" on other station. |
Feature: | Pocket Paging - With text message |
Default directory number: | 44 - during conversation |
Feature number: | 57 |
Parameter 1: | 0 (N/A) |
Description: | During conversation, dial 44 to activate the user’s pocket pager. The station cancels when the paging is on air. The pager display will show the number of the calling station. |
A station can activate the other station's remote control device (RCO) by pressing and releasing digit 6 during connection. If the station has remote control assigned, a success tone is given. The feature generates an event to the Event Handler, where the actual remote control takes place. The feature has timing so that the event is reported OFF after 3,5 seconds (programmable).