Add new ASVP alarm messages (MDF)
From Zenitel Wiki
- The ASVP board can store a large number of alarm messages. In the MDF file there is mapping information saying which alarm message in the ASVP corresponds to which alarm message id in AMC. As a default 9 alarm messages are mapped in the MDF file.
- When using ASVP board with more than 9 alarm messages the MDF file needs to be modified
- Before you go on, make a backup of your mdf file. In the directory AlphaPro -> Exchgs -> your exchange you will find a file with the extension .mdf. Make a backup copy of the file.
- The different alarm messages are defined in a table in the ASVP.
Directory number | Alarm message id: | Group, individ: |
8191 | 1 | 4, 10 |
8192 | 2 | 4, 11 |
8193 | 3 | 4, 13 |
8194 | 4 | 4, 14 |
8195 | 5 | 4, 15 |
8196 | 6 | 4, 16 |
8197 | 7 | 4, 17 |
8198 | 8 | 4, 18 |
8199 | 9 | 4, 19 |
4, 20 | ||
4, 21 | ||
4, 22 | ||
4, 23 | ||
4, 24 | ||
4, 25 | ||
4, 26 |