Actions

Difference between revisions of "8023 IP station - Release Notes"

From Zenitel Wiki

m (Text replacement - "<br\>" to "<br />")
Line 1: Line 1:
'''Software in production:''' ---<br\>
+
'''Software in production:''' ---<br />
'''Software released date:''' ---<br\>
+
'''Software released date:''' ---<br />
'''Bootloader in production:''' ---<br\>
+
'''Bootloader in production:''' ---<br />
'''Bootloader released date:''' ---<br\>
+
'''Bootloader released date:''' ---<br />
<br\>
+
<br />
  
 
=Later versions (from 2009-05-05) =
 
=Later versions (from 2009-05-05) =
This software "A100G80232.xxxx" is now obsolete, and replaced by "A100G80200.xxxx".<br\>
+
This software "A100G80232.xxxx" is now obsolete, and replaced by "A100G80200.xxxx".<br />
 
For later software versions for the 8023 IP master station, see [[Release Notes CCoIP station sw|Software for 8022, 8023, 8024 station (IP substations and IP master stations)]].
 
For later software versions for the 8023 IP master station, see [[Release Notes CCoIP station sw|Software for 8022, 8023, 8024 station (IP substations and IP master stations)]].
  
Line 14: Line 14:
 
  DIP protocol version 00.04.
 
  DIP protocol version 00.04.
  
'''System upgrade file:'''<br\>
+
'''System upgrade file:'''<br />
Image: A100G80232.0106.bin<br\>
+
Image: A100G80232.0106.bin<br />
 
Checksum: 3A140733
 
Checksum: 3A140733
<br\><br\>
+
<br /><br />
  
 
== Errors corrected  ==
 
== Errors corrected  ==
Line 31: Line 31:
 
=== BZ 34: IP sub: Don't work after AMC-IP  change ===
 
=== BZ 34: IP sub: Don't work after AMC-IP  change ===
 
When swapping the AlphaCom AMC boards between two configured with the same IP address (redundancy), the IP station would not reconnect properly. Fixed.
 
When swapping the AlphaCom AMC boards between two configured with the same IP address (redundancy), the IP station would not reconnect properly. Fixed.
<br\>
+
<br />
  
 
== Functional changes / Enhancement ==
 
== Functional changes / Enhancement ==
Line 52: Line 52:
 
  DIP protocol version 00.04.
 
  DIP protocol version 00.04.
  
'''System upgrade file:'''<br\>
+
'''System upgrade file:'''<br />
Image: A100G80232.0105u3.bin<br\>
+
Image: A100G80232.0105u3.bin<br />
 
Checksum: 9E961734
 
Checksum: 9E961734
<br\><br\>
+
<br /><br />
  
 
First release.
 
First release.
  
<br\><br\><br\><br\>
+
<br /><br /><br /><br />
  
 
=A100G80231.0002c (2008-05-07)=
 
=A100G80231.0002c (2008-05-07)=
Bootloader for 8023 IP master station, PCB revision 3.<br\>
+
Bootloader for 8023 IP master station, PCB revision 3.<br />
 
  hw_type = 8023
 
  hw_type = 8023
 
  hw_version = 3
 
  hw_version = 3
  
 
=A100G80231.0002a (2008-01-30)=
 
=A100G80231.0002a (2008-01-30)=
Bootloader for 8023 IP master station, PCB revision 1.<br\>
+
Bootloader for 8023 IP master station, PCB revision 1.<br />
 
  hw_type = 8023
 
  hw_type = 8023
 
  hw_version = 1
 
  hw_version = 1

Revision as of 12:20, 8 March 2016

Software in production: ---
Software released date: ---
Bootloader in production: ---
Bootloader released date: ---

Later versions (from 2009-05-05)

This software "A100G80232.xxxx" is now obsolete, and replaced by "A100G80200.xxxx".
For later software versions for the 8023 IP master station, see Software for 8022, 8023, 8024 station (IP substations and IP master stations).

A100G80232.0106 (2008-09-12)

Release: Official, available on request
DIP protocol version 00.04.

System upgrade file:
Image: A100G80232.0106.bin
Checksum: 3A140733

Errors corrected

(BZ = Bugzilla reference number)

LCD font

Font size 8x15 is now printed correctly. Height was incorrectly 16 pixels.

Simplex audio

In simplex (e.g. remote M-key), the loudspeaker audio was unstable. Improved by turning off the DSP's NLP (Non Linear Processor) in this mode.

Ethernet disconnection issue

If network cable was disconnected and an event (input) occurred immediately after that, the disconnection would not be detected until after about 20 minutes. Fixed.

AlphaCom reconnection attempt

If the AlphaCom didn't have IP station licenses the station would not connect, and neither make an attempt to reconnect. Now it will try to reconnect and will come up when the IP station licenses are installed. (Previous workaround: Restart the IP station or AlphaCom.)

BZ 34: IP sub: Don't work after AMC-IP change

When swapping the AlphaCom AMC boards between two configured with the same IP address (redundancy), the IP station would not reconnect properly. Fixed.

Functional changes / Enhancement

LCD shows privacy state

A large "PRIVATE" or "OPEN" icon is displayed on LCD when privacy state is changed, and a "P" icon is blinking in top right corner in "PRIVATE" state. Hold C-key for 2 seconds in idle to change state.

M-key supported

M-key audio control ("auo" message) now supported.

LCD cursor

Added support for LCD cursor.

TCP disconnection

Changed behavior upon TCP disconnection. Now the relay output, station LED and any playing tone is reset upon disconnection.

LCD supports foreign language characters

Added support for new characters: Norwegian, German, Hebrew, etc.


A100G80232.0105u3 (2008-05-07)

Release: Official, available on request
DIP protocol version 00.04.

System upgrade file:
Image: A100G80232.0105u3.bin
Checksum: 9E961734

First release.





A100G80231.0002c (2008-05-07)

Bootloader for 8023 IP master station, PCB revision 3.

hw_type = 8023
hw_version = 3

A100G80231.0002a (2008-01-30)

Bootloader for 8023 IP master station, PCB revision 1.

hw_type = 8023
hw_version = 1

First release.