Actions

Difference between revisions of "ATLB - AlphaCom Telephone Line Board"

From Zenitel Wiki

(Technical Specification)
Line 89: Line 89:
 
|-
 
|-
 
|}
 
|}
.
+
<br style="clear:both;" />
  
 
==Related articles==
 
==Related articles==

Revision as of 11:25, 7 August 2014

ATLB Telephone Line Board

Note: The ATLB board is obsolete and is replaced by the ATLB-12 board.

Features

ATLB card with jumpers
  • Is used for 2-wire connection of telephones as stations in an AlphaCom system
  • Each board provides 6 telephone connections and 1 voice-switched conversation
  • 6 remote control outputs (software configurable activation)
  • Hotline function
  • DTMF dialing
  • R-button detection
  • Selectable -48V or -24V battery feed
  • 600 ohm or complex impedance hybrid balance
  • Line monitoring using resistor in parallel with phone
  • Hot-plug in and out of the board
  • Red/green/amber LED indicates system status
  • Different types of connection boards available


Description

The ATLB board contains circuitry for connection of 6 2-wire telephones as AlphaCom subscribers. The board also provides one measurement channel for voice switching control. It plugs into any position 1 - 23.

When the hot-line function is activated for the station a preprogrammed number is dialed when the handset is lifted. When the handset is replaced, another number is dialed.

The board provides 6 remote control outputs RCO that are software-controlled (4 RCO's in AlphaCom E7). The line monitoring reports errors on all subscriber lines. If the handset is left off for 1 hour (programmable timer) a line error is reported.

The board can be plugged in/out while the exchange is running. A hot plug-in cable is needed for this purpose. The cable is included in the cable set for the exchange.

Connection Boards

Connection Board ATLB
Connection Board Prot/Ring ATLP

The standard connection board provides connection for 6 analogue telephones and 6 RCO outputs.

The ATLB provides connection for 6 analogue telephones and 6 RCO outputs. In addition the board provides protection against heavy transients and a ring voltage generator. This board is used when the subscriber cabling may be exposed to heavy transients and should always be used if there are outdoor cables. The ring voltage generator is needed when there are several phones in parallel on the same line, or the lines are very long.

AlphaCom E20/E26

Telephones and control outputs are connected to a connection board mounted on the exchange connection field.

Telephone connection board with transient protection (100 9930 202) and subscriber connection cable with filter board (100 9501 031) must be purchased separately.

AlphaCom E7

All telephones are connected by means of pluggable screw terminals on the exchange back-plane.

Note: When the ATLB board is used in AlphaCom E7 only four RCO's are available.

Installation Overview

Telephone connection to ATLB in E20 and E26
Telephone connection to ATLB in E7


Technical Specification

Order Number: 1009102000
Operation Voltage 5, 15, 24, 32 V DC
Dimensions (WxHxD) 10mm x 230mm x 263mm <br\> 0.39"x 8.97"x 10.26" <br\> Double Extended Europe Format
S/N ratio (conversation) 45 dB
Input impedance: 600 ohm
Frequency range conversation: 300 - 3,400 Hz
Crosstalk at 1 kHz: <- 75 dB
Capacity for each ATLB board 6 subscribers
Duplex-controlled conversations 1 voice-switched conv. per board
Remote control outputs: 5V 2.2 kOhm
Cable type : <br\> 1-pair twisted cable per station
Max cable length to station 0.5 mm2: 6km <br\> 0.6 mm2: 8km
0.9 mm2: 10km
Distortion: <2%
Indicator: LED (red/green/amber)


Related articles