Actions

Difference between revisions of "AlphaCom XE1"

From Zenitel Wiki

(Connections)
(Connections)
Line 12: Line 12:
 
===<u>Connections</u>===
 
===<u>Connections</u>===
 
====Power====
 
====Power====
 +
* The exchange is normally powered from the mains via a 5 VDC power supply
 +
 
====Network====
 
====Network====
 +
* Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
 +
 
====Serial Ports====
 
====Serial Ports====
====RCI====
 
====RCO====
 
 
[[File:XE1 Connections.png|thumb|left|500px]]
 
<br style="clear:both;" />
 
* The exchange is normally powered from the mains via a 5 VDC power supply
 
* Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
 
* There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
 
 
* The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
 
* The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
  
Line 46: Line 42:
 
[[File:SerialPortJumpers XE1.png|thumb|left|500px|RS422/485 selector for Serial Port 1 in the XE1]]
 
[[File:SerialPortJumpers XE1.png|thumb|left|500px|RS422/485 selector for Serial Port 1 in the XE1]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
 +
====RCI====
 +
* There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
 +
 +
====RCO====
 +
* XE1 does not support any RCO's in the server itself. If remote control outputs are required, please use [[TKIS-2|TKIS-2 kit]] or [[IP-ARIO.]]
 +
 +
[[File:XE1 Connections.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 +
 +
 +
  
  
 
[[Category:AlphaCom Servers]]
 
[[Category:AlphaCom Servers]]

Revision as of 11:46, 4 November 2016

AlphaCom XE1 Audio Server with HD Voice

Highlights

  • Made to provide critical communication in any environment
  • Supports 552 IP stations
  • Environmental friendly and energy saving - max. 4 W
  • SIM card based software configuration and disaster recovery
  • Fully compatible with any AlphaCom system

Additional Documentation on Zenitel.com

Connections

Power

  • The exchange is normally powered from the mains via a 5 VDC power supply

Network

  • Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming

Serial Ports

  • The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
XE1 IP and serial connections


Serial Ports

Serial Port 0 - 9-Pin D-sub (RS232 Only)

No additional settings necessary

Serial Port 1 - RJ45 (RS232/422/485)

Additional settings:
RS232:
RS422/485:
  • Switch 8 on S601 on the AMC-IP board must be set to ON.
  • Take off the top lid to reach the jumpers inside, and set them to the correct position.
- RS485: Both jumpers in position 2-3 (default)
- RS422: Both jumpers in position 1-2
RS422/485 selector for Serial Port 1 in the XE1


RCI

  • There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors

RCO

  • XE1 does not support any RCO's in the server itself. If remote control outputs are required, please use TKIS-2 kit or IP-ARIO.