AlphaVision - Example configuration

This article gives step-by-step instructions how to get started with AlphaVision. Main configuration steps are:

  • AlphaWeb: Enable TCP port 55010
  • AlphaPro: Activate ACDP link and Device 64
  • AlphaVision: Configure communication parameters (AVCMSetup) and select 'Operator station'


AlphaWeb

  • In System Configuration -> Filters, enable TCP port 55010 on the ethernet port used for AlphaVision.

AlphaPro

  • In Exchange & System -> Serial ports, activate a communication port to be used for AlphaVision. Select one of the seven ACDP Links, and set the following parameters:
    • Port Type: TCP/IP Server
    • Link Type: Stentofon MultiDrop Master - Reserved
    • Broadcast: Enabled
    • Destination: AlphaVision (optional)
    • Port: 55010
    • Keep Alive: Enabled
AlphaPro: Serial Ports setting


    • Device type: Operator (passive)
    • Data (ACDP link): select the link which was configured in the Serial Ports window
AlphaPro: Device settings


AlphaVision

Setup

  • Download and install AlphaVision on a PC. Latest software version is available on the download site.
  • Start the 'AVCMSetup' program (Windows XP: Start-> All Programs -> AlphaVision: AVCMSetup). Set:
    • Communiation Type: IP
    • AC E IP address: The IP address of the AlphaCom
    • Normally one can leave the other parameters as is. Press OK to close the window.
AlphaVision: AVCMSetup


  • Start the AlphaVision program. Username = service, password = service (Supervisor login). The 'Message Window' at the bottom of the screen should show "Run Mode", and a green "eye" should appear at the bottom right corner of the PC, indicating the the communication between AlphaVision and AlphaCom is OK.
  • Select the 'System Tree' tab. AlphaVision will automatically detect stations as they are being used, and they will show up in the System Tree. An easy way to automatically detect all stations is to dial the code 7885 (Tone Test) from a SuperUser. Now all stations will detected one by one. (Initially only Station 102 will appear in the System Tree, as this is the default operator station. Double click on station 102 to open the tree to see all stations).
  • Assign an 'Operator station' to AlphaVision by selecting Configuration -> Options -> Systems tab. By default station 102 in node 1 is set as operator station if found, and no other station is defined.
AlphaVision screenshot - Communication OK and stations are detected and shown in the System Tree


Operation

When a Call Request is made to the 'Operator Station' (e.g. a station dials 623 + 102), the call will appear in the Call Request list, and an "Accept" button will appear. The call is answered by clicking the "Accept" button, or by double clicking the station in the call request list. During conversation a "Cancel" button will appear to terminate the conversation.

In 'Configuration -> Maps' you can create or import a map. From the 'System Tree' you can drag stations and drop them on the map, and they will appear as icons on the map. The icons will automatically show the call status of the station. Rightclick the icon to assign more properties to it.