Difference between revisions of "IND - Indicator control for CRMIV LEDs, buzzer etc."

From Zenitel Wiki

Line 55: Line 55:
 
:3 = fast flash <br>  
 
:3 = fast flash <br>  
 
|-
 
|-
| align=center| '''[state]''' ||colspan="3" align=center|The brackets [ ] indicate that this command is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.  
+
| align=left| '''[state]''' ||colspan="3" align=center|ON or OFF (capital letters) <br>
ON or OFF (capital letters)
+
The brackets [ ] indicate that this command is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.  
 
|-
 
|-
 
|}
 
|}
 
 
'''station phys.no''':
 
:*1-552 = The physical number of the station
 
 
'''key no.''':
 
:*1-100 = The key number of the DAK-key <br>
 
:*1023 = Buzzer
 
:*1024 = Display backlight
 
 
'''Led no/buzzer''': <br>
 
:If the previous parameter was DAK-key (1 - 100):
 
:*1 = Red LED
 
:*2 = Green LED
 
 
:If the previous parameter was Buzzer (1023):
 
:*1 = Internal buzzer
 
:*2 = External buzzer (relay)
 
 
:If the previous parameter was Display (1024):
 
:*1 = Backlight
 
 
'''Ind-type''':
 
:LEDs and display:
 
:*1 = continuous (low priority)
 
:*2 = slow flash (medium priority)
 
:*3 = fast flash (high priority)
 
 
:Buzzers:
 
:*1 = 1 bleep per 8 seconds (low priority)
 
:*2 = 1 bleep per 2 seconds (medium priority)
 
:*3 = 4 bleeps per second (high priority)
 
:*4 = continuous (alarm priority)
 
 
 
'''[state]''':
 
:*ON or OFF (capital letters)
 
:The brackets [ ] indicate that this command is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.
 
  
  

Revision as of 01:15, 11 November 2007

The IND (INDication) action is used for sending commands to a station. The commands are sent as display data. The following stations are currently using the IND command:

  • CRM IV: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display
  • DualDisplay station: Control the video-state of the DAK-display
  • Priscom station: Control the outputs used for lamps, cell light, call LED and spare output

The command syntax:

IND <station phys.no> <output> <LED no/buzzer> <Ind-type> [state]

Parameter description

Between the command parameters, there must always be a space.

Station Connect Operations

Message CRM IV DualDisplay PrisCom
station phys.no 1 - 552 = The physical number of the station
output 1-100 = The key number of the DAK-key
1023 = Buzzer
1024 = Display backlight
1-100 = The DAK-line 1 - 4 = Lamp outputs
5 - 6 = Spare outputs
7 = Cell light
8 = Call LED
LED no/buzzer DAK-key:
1 = Red LED
2 = Green LED

Buzzer:

1 = Internal buzzer
2 = External buzzer (relay)

Display backlight:

1 = Backlight
Always "1" Always "1"
Ind-type DAK LED's:
1 = continuous (low priority)
2 = slow flash (medium priority)
3 = fast flash (high priority)

Buzzers:

1 = 1 bleep per 8 seconds (low priority)
2 = 1 bleep per 2 seconds (medium priority)
3 = 4 bleeps per second (high priority)
4 = continuous (alarm priority)

Display backlight:

1 = continuous
Video-state of the DAK-display:
0 = Normal
1 = Inverse
2 = Slow flash
3 = Fast flash
Output state:
1 = continuous
2 = slow flash
3 = fast flash
[state] ON or OFF (capital letters)

The brackets [ ] indicate that this command is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.


Example

IND  2  23  2  3  ON – Station 2, key 23, turn green led, fast flashing, ON