Actions

Difference between revisions of "IP-ARIO Restore Factory Defaults"

From Zenitel Wiki

(Factory Default IP Settings)
m (1 revision imported)
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
To configure the IP-ARIO unit with Factory Default IP Settings do the following:
+
[[File:IP-ARIOConfig10.PNG|thumb|right|400px|iP-ARIO - Front view]]
 +
To configure the [[IP-ARIO]] unit with Factory Default IP Settings do the following:
 
# Disconnect power to the unit. <br/>
 
# Disconnect power to the unit. <br/>
 
# Reconnect power and within 5 seconds, use a pin to press and hold the pinhole Reset button (on the front right of the unit).
 
# Reconnect power and within 5 seconds, use a pin to press and hold the pinhole Reset button (on the front right of the unit).
 
# Keep the Reset button pressed until the CALL LED emits 3 slow flashes followed by 3 fast flashes as confirmation that the unit is reset. (Takes appr. 25 seconds)
 
# Keep the Reset button pressed until the CALL LED emits 3 slow flashes followed by 3 fast flashes as confirmation that the unit is reset. (Takes appr. 25 seconds)
 
# Release the Reset button.
 
# Release the Reset button.
The unit’s IP settings will now be reset to the factory default values with IP address 169.254.1.100.
+
The unit’s IP settings will now be reset to factory default.
[[File:IP-ARIOConfig10.PNG|thumb|left|400px|Front view]]
 
<br style="clear:both;" />
 
  
 
{| class="wikitable"  
 
{| class="wikitable"  
Line 24: Line 23:
  
 
  * Software 01.06 and earlier: '''ADMIN/alphacom''')
 
  * Software 01.06 and earlier: '''ADMIN/alphacom''')
 +
 +
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 15:10, 5 February 2018

iP-ARIO - Front view

To configure the IP-ARIO unit with Factory Default IP Settings do the following:

  1. Disconnect power to the unit.
  2. Reconnect power and within 5 seconds, use a pin to press and hold the pinhole Reset button (on the front right of the unit).
  3. Keep the Reset button pressed until the CALL LED emits 3 slow flashes followed by 3 fast flashes as confirmation that the unit is reset. (Takes appr. 25 seconds)
  4. Release the Reset button.

The unit’s IP settings will now be reset to factory default.

Factory default values
Station Mode AlphaCom
Station IP address 169.254.1.100
AlphaCom IP address 169.254.1.5
Username* admin
Password* alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)