Q: MultiModule over IP: After having converted an AlphaCom to an AlphaCom E, the Master module cannot find the Slave module.<br> | Q: MultiModule over IP: After having converted an AlphaCom to an AlphaCom E, the Master module cannot find the Slave module.<br> | ||
A: In AlphaPro, '''Exchange & System''' > '''Serial Ports''' select ''Inter Module'' protocol. Make sure '''Port Type''' = N/A, and that the '''Enable''' flag is unchecked. | A: In AlphaPro, '''Exchange & System''' > '''Serial Ports''' select ''Inter Module'' protocol. Make sure '''Port Type''' = N/A, and that the '''Enable''' flag is unchecked. | ||
− | |||