Actions

Difference between revisions of "Noise Cancelling Industrial Master Station - 1007082000"

From Zenitel Wiki

(Features)
(Description)
Line 11: Line 11:
  
 
== Description ==
 
== Description ==
This industrial master station is a waterproof model designed
+
This industrial master station is a waterproof model designed for humid, dirty and outdoor conditions. The station consists of a rugged splashproof and
for humid, dirty and outdoor conditions. The unit can operate
+
chip-resistant casing of orange makrolon and has a folio keyboard on the front. The front panel is hinged to the back casing to allow easy access during installation and service. The station has screw terminals with labels for easy installation. Two glands ensure waterproof and dustproof connection of
in an ambient temperature range from -20oC to +50oC (-4oF
 
to +122oF). The station consists of a rugged splashproof and
 
chip-resistant casing of orange makrolon and has a folio
 
keyboard on the front. The front panel is hinged to the back
 
casing to allow easy access during installation and service.
 
The station has screw terminals with labels for easy installation.
 
Two glands ensure waterproof and dustproof connection of
 
 
installation cable and loudspeaker wires.
 
installation cable and loudspeaker wires.
  
The unit is equipped with a noise cancelling microphone
+
The unit is equipped with a noise cancelling microphone preventing background noise from disturbing the conversation. A 20-70 Ohm external loudspeaker connects to the station or, alternatively, connect an 8-20 Ohm speaker for use with the built-in 10W (8 Ohm) VOX operated power amplifier. The external speaker must be placed at least one meter away from the station. The power amplifier requires separate 12V AC / 2 Amp power supply. The loudspeaker volume is adjustable with potentiometers located inside the casing and the station is programmable for permanent private mode by strap-plug setting inside the station.
preventing background noise from disturbing the conversation.
 
A 20-70 Ohm external loudspeaker connects to the station or,
 
alternatively, connect an 8-20 Ohm speaker for use with the
 
built-in 10W (8 Ohm) VOX operated power amplifier. The
 
external speaker must be placed at least one meter away from
 
the station. The power amplifier requires separate 12V AC / 2
 
Amp power supply.
 
  
The loudspeaker volume is adjustable with potentiometers
+
The station is prepared for connection of a separate external handset.
located inside the casing and the station is programmable for
 
permanent private mode by strap-plug setting inside the station.
 
 
 
The station is prepared for connection of a separate external
 
handset.
 
  
 
== Specifications ==
 
== Specifications ==

Revision as of 09:02, 25 October 2011

Noise Cancelling Industrial Master Station 100 7082 000.jpg

Features

  • Fully equipped master station with free access to all extensions and features.
  • Rugged waterproof and chip-resistant casing of orange makrolon.
  • Noise cancelling microphone with protective flange.
  • Red microphone live lamp.
  • Built-in 10W (8 Ohm) VOX operated power amplifier.
  • For use with external loudspeaker with or without power amplifier.
  • Screw terminals for easy connection of installation cables.

Description

This industrial master station is a waterproof model designed for humid, dirty and outdoor conditions. The station consists of a rugged splashproof and chip-resistant casing of orange makrolon and has a folio keyboard on the front. The front panel is hinged to the back casing to allow easy access during installation and service. The station has screw terminals with labels for easy installation. Two glands ensure waterproof and dustproof connection of installation cable and loudspeaker wires.

The unit is equipped with a noise cancelling microphone preventing background noise from disturbing the conversation. A 20-70 Ohm external loudspeaker connects to the station or, alternatively, connect an 8-20 Ohm speaker for use with the built-in 10W (8 Ohm) VOX operated power amplifier. The external speaker must be placed at least one meter away from the station. The power amplifier requires separate 12V AC / 2 Amp power supply. The loudspeaker volume is adjustable with potentiometers located inside the casing and the station is programmable for permanent private mode by strap-plug setting inside the station.

The station is prepared for connection of a separate external handset.

Specifications

Operating Voltage From exchange without power amp. 12VAC/2Amp with power amp.
Cable Requirements 2 pair 0.5mm²/24AWG twisted telephone cable.
+ 1 pair 0.8mm²/20AWG (to transformer if power amplifier is used)
Temperature -50˚C to +55˚C
Relative humidity 0% - 95%
Dimensions: (WxHxD) 160 x 240 x 137 mm, 6.24" x 9.36" x 5.34"
Finish Orange makrolon
Max. Loudspeaker Output 1.5W (20 Ohm), 10W (8 Ohm) with power amplifier
Loudspeaker Impedance 20-70 Ohm without power amplifier, 8-20 Ohm with power amplifier
Frequency Range 500-5000 Hz (± 8dB)
Mic. Impedance for external handset 200 - 600 Ohm
Connector Type Screw terminals
Gland Diameter 2 x PG9
Indicator LED (red)

Installation

Noise Cancelling Industrial Master Station 100 7082 000 Installation.jpg









Wiring

Noise Cancelling Industrial Master Station 100 7082 000 Wiring.jpg