RCO - Remote Control Output

From Zenitel Wiki

Revision as of 13:41, 5 May 2022 by Asle (talk | contribs) (Devices supporting RCOs)
AI.png
Examples of RCO usage

The Remote Control Output RCO’s are used to operate relays for control of external equipment.

Relay outputs are typically used for:

  • Door opening
  • PA control
  • Call indication
  • Queue indication
  • Keying of mobile radio transmitter
  • CCTV interface


Logical RCOs

There are several ways to control RCOs. Most common is to use Logical RCOs operated by the RCO command.

  • The RCO command operates a Logical RCO
  • Each logical RCO must be mapped to a Device or Station, and to a Pin Number
  • The ICX-AlphaCom (and AlphaCom XE) supports up to 500 logical RCOs.
  • The operation of the logical RCOs is configured from AlphaPro, in the Event Handler window.

Mapping of RCOs

The mapping of RCOs is done from AlphaPro, Exchange & System -> RCO window where the logical RCO is assigned to a physical address.

The physical address is given as:

  • Station + Pin Number, or by
  • Device + Pin Number.
Note icon "Device" is not supported in the ICX-AlphaCom server. Here you should always use "Station".


AlphaPro: Exchange & System > RCO window


RCO Number: The "logical" number of the RCO. Use this number in the RCO command.
Description: Any descriptive text. This information is stored in the AlphaPro database only, and is not sent to the exchange.
RCO Type: Device: (AlphaCom XE servers only) The device ID

Station: IP Station, Turbine, IPARIO, IP-LCM or ENA amplifier

Device:
  • 65 = AlphaCom
  • 1-64 = RIO unit adress
  • When 'RCO Type' is set to Station, enter the physical number of the IP Station, Turbine station or the IPARIO
Pin Number:
  • AlphaCom: Pin 1 - 552 (the same as the physical number of stations)
  • RIO unit: Pin 1 - 18
  • IPARIO unit: Pin 1 - 8
  • IP Station: Pin 1 - 2 (the relay is pin 1)
  • Turbine compact: Pin 1 - 7 (the relay is pin 7)
  • Turbine Industry: Pin 1 - 10 (the relays are pin 7-10)
  • ENA Amplifier: Pin 1 - 6
  • IP-LCM: Pin 1 - 7 (the TKIS-2 relay is pin 7), pin 17-24 (external relays)


  • RCO 1-138 are by default mapped to the internal RCOs in the AlphaCom, i.e. device 65 - pin 1 to device 65 - pin 138
  • Mappings for all other RCOs must be configured manually
  • The RCOs can be used freely within the system, e.g. an event on one station can operate an RCO located on a different station.
  • The exchange always keeps track of the state of an output in case the device becomes faulty. When a faulty device becomes OK again, the exchange will restore the current RCO state.

Configuration examples

The Event Handler is used to configure the behavior of the RCOs. Here are some examples:


Other RCO related commands

Built-In Action Commands:

  • IND command: Direct operation of an output on an IP station or Turbine station. This command does not use logical RCO, so there is no need for RCO mapping.
    • Example: IND 14 5 1 1 ON On physical number 14, output 5, turn ON (Assuming a Turbine station)


ACDP commands:

  • $X (EXECUTE_COMMAND): Sends a command string to a remote exchange to be executed there. Requires RCO mapping.
    • Example: @4 $X "RCO 2 ON": Turn on RCO 2 in node 4


  • $SLRC (SET LOGICAL RCO): Set or clear a logical RCO. Requires RCO mapping.
    • Example: $SLRC W5 U1 W25: Turn RCO #5 ON for 2.5 seconds


  • $SET_IPRCO: Direct operation of an output on an IP station, Turbine station or IPARIO. This command does not use logical RCO, so there is no need for RCO mapping.
    • Example: $SET_IPRCO L234 U3 U1: On station number 234, turn output number 3 ON


Event Handler macros:

  • %prco: The %prco macro is used in the Event Handler to check state of a physical output on an IP-ARIO.
    • Example: %prco(5,1): Return the state of output 1 on IPARIO station 5

Software

  • AMC 10.50 or later to control RCOs in slave modules. Earlier AMC versions support RCOs in master module only (pin 1 - 138).
  • AMC 10.04: Additional parameter to pulse the RCO ('RCO 12 ON 20' to generate a 2.0 sec pulse on RCO 12)
  • AMC 07.40 or later to control RCOs in an AlphaNet installation.