Actions

Difference between revisions of "TFIE Indication LEDs"

From Zenitel Wiki

(LEDs on Front Plate)
(Status LEDs on PCB)
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
== LEDs on Front Plate ==
+
== LEDs in Front Panel ==
 
[[File:TFIE Indications 1.PNG|thumb|left|200px]]
 
[[File:TFIE Indications 1.PNG|thumb|left|200px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
*'''Power (Green):''' Steady light when power is OK
 +
*'''Fault (Yellow):''' Flashing when the station is not registered/no connection to server
 +
*'''Call (Red):''' Steady light during a conversation/call
  
*'''Power LED (Green):''' Steady light when power is OK
+
<br>
*'''Fault LED (Yellow):''' Flashing when the station is not registered/no connection to server
+
 
*'''Call LED (Red):''' Steady light during a conversation/call
+
== LEDs in Function Keys/DAK keys ==
 +
When a TFIE station is used in AlphaCom mode, the LEDs in the DAK keys can be controlled from the [[Event Handler]] by using the [[IND|IND command]].
 +
 
 +
<br>
  
 
==Status LEDs on PCB==
 
==Status LEDs on PCB==
 
[[File:TFIE Board Indications 1.png|thumb|left|500px]]
 
[[File:TFIE Board Indications 1.png|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
'''Flashing 2 red + 1 green:'''
+
Two LEDs (green and red) indicates if the station is registered.
* Station has no connection to the AlphaCom server/exchange.
+
*'''Flashing green''': Station is successfully registered to the server/controller
 
+
*'''Flashing two times red + one time green''' or '''one red + two green''': The station fails to register. Check the network, IP settings and account settings in the station and account settings, firewall, license and configuration in the server/controller
'''Flashing 1 red + 2 green:'''
 
* Station connected but NOT registered in the AlphaCom server/exchange.
 
  
'''Flashing 3 green'''
+
<br>
* Station connected and registered in the AlphaCom server/exchange.
 
  
 
==Ethernet Activity & Speed LEDs on PCB==
 
==Ethernet Activity & Speed LEDs on PCB==
Line 33: Line 36:
  
  
[[Category:Turbine Indication LEDs]]
+
[[Category: Station Indication LEDs]]

Latest revision as of 13:42, 20 November 2020

LEDs in Front Panel

TFIE Indications 1.PNG


  • Power (Green): Steady light when power is OK
  • Fault (Yellow): Flashing when the station is not registered/no connection to server
  • Call (Red): Steady light during a conversation/call


LEDs in Function Keys/DAK keys

When a TFIE station is used in AlphaCom mode, the LEDs in the DAK keys can be controlled from the Event Handler by using the IND command.


Status LEDs on PCB

TFIE Board Indications 1.png


Two LEDs (green and red) indicates if the station is registered.

  • Flashing green: Station is successfully registered to the server/controller
  • Flashing two times red + one time green or one red + two green: The station fails to register. Check the network, IP settings and account settings in the station and account settings, firewall, license and configuration in the server/controller


Ethernet Activity & Speed LEDs on PCB

TFIE Board Indications 2.png


Green LED:

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED:

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection