Actions

TFIE Indication LEDs

From Zenitel Wiki

Revision as of 09:32, 12 April 2019 by Asle (talk | contribs)

LEDs on Front Plate

Power LED - Green:

  • Steady light: Power is OK

Fault LED - Yellow:

  • Steady light: Not used
  • Flashing: Not registered/no connection to server

Call LED - Red:

  • Steady light: In a conversation/call
TFIE Indications 1.PNG


Status LEDs on PCB

TFIE Board Indications 1.png


Flashing 2 red + 1 green:

  • Station has no connection to the AlphaCom server/exchange.

Flashing 1 red + 2 green:

  • Station connected but NOT registered in the AlphaCom server/exchange.

Flashing 3 green

  • Station connected and registered in the AlphaCom server/exchange.

Ethernet Activity & Speed LEDs on PCB

TFIE Board Indications 2.png


Green LED:

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED:

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection