Actions

Difference between revisions of "Advanced Output handler (ENA in SIP mode)"

From Zenitel Wiki

(Event Actions)
(Trigger Output during call to specific number)
 
(2 intermediate revisions by the same user not shown)
Line 31: Line 31:
 
Action control an Output, and multiple IO's can be controlled in the same Event.  
 
Action control an Output, and multiple IO's can be controlled in the same Event.  
  
States can be same as in basic relay handling: steady off, steady on and timed steady on.  
+
States can be: steady off, steady on and timed steady on.  
  
 
[[File:ENA aoh event action operation.png|thumb|left|700px|Event action operation]]
 
[[File:ENA aoh event action operation.png|thumb|left|700px|Event action operation]]
Line 37: Line 37:
  
 
==Example==
 
==Example==
===Trigger Relay during call to specific number===
+
===Trigger Output during call to specific number===
In this example the Relay will only be triggered if the station is in or attempting a call to the number 911.  
+
In this example the output will only be triggered if the amplifier is in a call to the number 401.  
[[File:aoh_event_example_relayduringcall.png|thumb|left|500px|Relay during call - example]]
+
[[File:ENA aoh example.png|thumb|left|700px|Output on during call - example]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
+
[[Category: Public Address - Features and configuration]]
[[Category: SIP intercom - Configuration]]
 

Latest revision as of 13:31, 14 June 2024

SIP Icon 300px.png
ENA adv output.png


Event Triggers

Possible Event Triggers are

  • DTMF:
Will trigger an event on received DTMF. The action will stay on until next event happens.
  • Active Call
The station may in some situations have multiple calls, the active call is the call which has media/tone handling.
Can filter so it only triggers the event on
  • State: Ringing, Queued, In Call, On Hold
  • Direction: Incoming, Outgoing or Incoming/Outgoing
  • Channel: Channel 1, Channel 2, Input Channel
  • Directory Number: Can either directory number or a range for example 100-199
If the state In Call is selected, the output will stay set until the call has ended.
  • Registration Failed
Event is triggered if registration failed. The output action will be cleared on registration success.
  • Idle
Event is triggered when station goes back to Idle.


Event Actions

Action control an Output, and multiple IO's can be controlled in the same Event.

States can be: steady off, steady on and timed steady on.

Event action operation


Example

Trigger Output during call to specific number

In this example the output will only be triggered if the amplifier is in a call to the number 401.

Output on during call - example