Difference between revisions of "1-1b. AlphaWeb - Getting started (solution)"
From Zenitel Wiki
(→Configure Ethernet port 1) |
(→Configure filters) |
||
Line 21: | Line 21: | ||
===Configure filters=== | ===Configure filters=== | ||
*In AlphaWeb go to ''System Configuration -> Filters'' | *In AlphaWeb go to ''System Configuration -> Filters'' | ||
− | * | + | *For Eth1, enable the ports for AlphaWeb (http, port 80) and for AlphaPro |
*Press ''Save'' | *Press ''Save'' | ||
*Press ''Apply'' | *Press ''Apply'' |
Revision as of 15:23, 6 March 2014
PC Settings
- Configure your computer to have IP address 169.254.1.1
- Connect the PC to the ethernet port 0 of the AlphaCom using a standard ethernet cable
Login
- Use an internet browser like Internet Explorer to access AlphaWeb by typing in the exhcange default IP address: 169.254.1.5
- Default username: admin
- default password: alphaadmin
Configure Ethernet port 1
- In AlphaWeb go to System Configuration -> Interfaces
- Set the IP address on eth1 to 10.1.10.1/16 (.../16 means Subnet Mask = 255.255.0.0)
- Press Validiate, then Save & Apply
Configure filters
- In AlphaWeb go to System Configuration -> Filters
- For Eth1, enable the ports for AlphaWeb (http, port 80) and for AlphaPro
- Press Save
- Press Apply
- Press Yes