Actions

Difference between revisions of "1-3a. IP Stations – Master Stations (solution)"

From Zenitel Wiki

(Configure the IP Stations)
(IP Flush Master station)
Line 10: Line 10:
 
[[File:1-3a solution1.png|thumb|left|300px|Off-line menu: IP settings]]
 
[[File:1-3a solution1.png|thumb|left|300px|Off-line menu: IP settings]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
* '''Save'''. When asked for "Restart now" you can select "No".  
+
* When prompted, '''Save''' the changes. When asked for "Restart now" you can select "No".  
 
* Step to the menu selection '''AlphaCom IP''' and enter the following parameters:
 
* Step to the menu selection '''AlphaCom IP''' and enter the following parameters:
 
[[File:1-3a solution2.png|thumb|left|300px|Off-line menu: AlphaCom settings]]
 
[[File:1-3a solution2.png|thumb|left|300px|Off-line menu: AlphaCom settings]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
* When prompted, '''Save''' the changes.
 +
* Step to the menu selection '''Restart''' and activate a restart of the station
  
 
===Configure the AlphaCom XE===
 
===Configure the AlphaCom XE===

Revision as of 15:43, 22 March 2011

System configuration



Configure the IP Stations

IP Flush Master station

  • Connect the IP Flush Master station to the PoE switch
  • Select Setup to enter the off-line menu. Password: 1851
  • Step to the menu selection IP Settings and enter the following parameters (IPgw is not relevant here):
Off-line menu: IP settings


  • When prompted, Save the changes. When asked for "Restart now" you can select "No".
  • Step to the menu selection AlphaCom IP and enter the following parameters:
Off-line menu: AlphaCom settings


  • When prompted, Save the changes.
  • Step to the menu selection Restart and activate a restart of the station

Configure the AlphaCom XE

  • In AlphaPro go to Users & Stations, and select physical number 37; 137 Station 37
  • Use the section on the right and change the configuration as follows:
AlphaPro: Users & Stations


  • Send the changes to the AlphaCom
  • Check that the display on the station shows the correct number and name

DAK keys

  • In AlphaPro go to Users & Stations and select physical number 3
  • Click the DAK button in the lower left corner
  • Select the DAK 1-10 tab, and insert the following:
AlphaPro: Users & Stations -> DAK


  • Press DAK1 and observe that 416 Reception is called
  • Press DAK2 and observe that 6540 T. Edison is called


Additional information

When selecting Station Type = DualDisplay, the Navigation keys below the display are automatically configured. You can view the navigation key programming by selecting Users & Stations -> DAK -> Navig. Keys tab

  • Check that key 1-4 are:
    • I60 (Info menu)
    • I9543 (Page UP)
    • I9544 (Page DOWN)
    • I9542 (Menu)
Navigation keys


AlphaPro: Users & Stations -> DAK -> Navig keys







Related articles