There are 6 I/O connection options for the Turbine Compact Station.
 
There are 6 I/O connection options for the Turbine Compact Station.
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.  
+
These connections are used as relay contacts for door lock control and external I/O devices.  
  
 
For more details see [[Turbine Compact Board Connectors]]
 
For more details see [[Turbine Compact Board Connectors]]
  
 
[[Category: Turbine Connections]]
 
[[Category: Turbine Connections]]

Revision as of 10:32, 10 January 2017

APS.png
TCIS Connections
TCIS-X rear.PNG


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal


Power Supply

The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.

Network Connection

Turbine Compact top view


There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.

For more details see Turbine Compact Board Connectors