Actions

Difference between revisions of "TCIS Indication LEDs"

From Zenitel Wiki

Line 1: Line 1:
 +
{{APS}}
 
=LEDs on Front Plate=
 
=LEDs on Front Plate=
 
'''Status LEDs'''
 
'''Status LEDs'''

Revision as of 23:34, 9 January 2017

APS.png

LEDs on Front Plate

Status LEDs

- Bell icon lights yellow when a call is placed and ringing
- Talk icon lights green when a call is active and in conversation
- Door icon lights red when the door is unlocked or relay is active
TCIS Indications 1.PNG



Talk Icon: Flashing at 1 second intervals:
Station has no connection to the AlphaCom server/exchange.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom XE IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom server/exchange
TCIS Indications 2.PNG



Talk Icon: Flashing at 5 second intervals:
Station connected but NOT registered in the AlphaCom server/exchange.

Reason:

  • Station has not been programmed in AlphaPro
TCIS Indications 3.PNG


Status LEDs on PCB

TCIS Board Indications 1.png


Flashing 2 red + 1 green

  • Station has no connection to the AlphaCom server.

Flashing 1 red + 2 green

  • Station connected but NOT registered in the AlphaCom server.

Flashing 3 green

  • Station connected and registered in the AlphaCom server.

Ethernet Activity & Speed LEDs on PCB

TCIS Board Indications 2.png


Green LED

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection