Actions

Difference between revisions of "TCIS Restore Factory Defaults"

From Zenitel Wiki

(Reset to Factory Default Settings with Static IP)
Line 21: Line 21:
  
 
==Reset to Factory Default Settings with Static IP==
 
==Reset to Factory Default Settings with Static IP==
[[File:TCIS Factory Reset 2.PNG|thumb|200px|left|Factory Default with Static IP Address]]
 
<br style="clear:both;" />
 
  
 
To reset:
 
To reset:
Line 30: Line 28:
 
::- if there is no 0 count, the procedure has failed and you have to start again
 
::- if there is no 0 count, the procedure has failed and you have to start again
 
:4.  Press the '''call button''' to make the station say its IP address.
 
:4.  Press the '''call button''' to make the station say its IP address.
 +
 +
[[File:TCIS Factory Reset 2.PNG|thumb|150px|left|Factory Default with Static IP Address]]
 +
<br style="clear:both;" />
  
 
=== Factory default values ===
 
=== Factory default values ===

Revision as of 09:47, 27 October 2015

A Turbine IP Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.

Reset to Factory Default Settings with Activated DHCP

To reset:

1. While pressing any button, power up the station by connecting to a PoE switch.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 5 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button to make the station say its IP address.
Factory Default with IP address from DHCP server


Factory default values

Station IP address: (determined by DHCP server)
Username: admin
Password: alphaadmin


Reset to Factory Default Settings with Static IP

To reset:

1. While pressing any button, power up the station by connecting to a PoE switch.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 3 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button to make the station say its IP address.
Factory Default with Static IP Address


Factory default values

Station IP address: 169.254.1.100 Username: admin Password: alphaadmin