Actions

TFIE Indication LEDs: Difference between revisions

From Zenitel Wiki

Line 24: Line 24:


=Ethernet Activity & Speed LEDs on PCB=
=Ethernet Activity & Speed LEDs on PCB=
[[File:TFIE Indications 3.PNG|thumb|700px]]
[[File:TFIE Board Indications 2.png|thumb|left|500px]]
'''<u>Green LED</u>'''
<br style="clear:both;" />
:- Steady light:  Ethernet connection OK
:- Flashing:  Ethernet data traffic
:- No light:  No Ethernet connection


'''<u>Yellow LED</u>'''
'''Green LED:'''
:- Steady light: 100 Mbit Ethernet connection  
* Steady light: Ethernet connection OK
:- No light:   10 Mbit Ethernet connection
* Flashing: Ethernet data traffic
* No light: No Ethernet connection
 
'''Yellow LED:'''
* Steady light: 100 Mbit Ethernet connection  
* No light: 10 Mbit Ethernet connection


<br style="clear:both;" />


[[Category:Turbine]]
[[Category:Turbine]]

Revision as of 12:47, 13 October 2016

LEDs on Front Plate

Power LED - Green:

  • Steady light: Power is OK

Fault LED - Yellow:

  • Steady light: Not used
  • Flashing: Not registered/no connection to server

Call LED - Red:

  • Steady light: In a conversation/call
TFIE Indications 1.PNG


Status LEDs on PCB

TFIE Board Indications 1.png


Flashing 2 red + 1 green:

  • Station has no connection to the AlphaCom server/exchange.

Flashing 1 red + 2 green:

  • Station connected but NOT registered in the AlphaCom server/exchange.

Flashing 3 green

  • Station connected and registered in the AlphaCom server/exchange.

Ethernet Activity & Speed LEDs on PCB

TFIE Board Indications 2.png


Green LED:

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED:

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection