Actions

Difference between revisions of "Turbine Software Upgrade"

From Zenitel Wiki

(Upgrade using the Web Interface of the station)
Line 1: Line 1:
This article describes how to upgrade the software of the [[Turbine series|Turbine series of intercom devices]] to version 4.2.3.6. Note that there is a separate Upgrade procedure for [[IP Station Software upgrade|INCA IP stations]].
+
This article describes how to upgrade the software of the [[Turbine series|Turbine series of intercom devices]] to version 4.2.3.9. Note that there is a separate Upgrade procedure for [[IP Station Software upgrade|INCA IP stations]].
  
 
There are two recommended ways of upgrading the software on the Turbine station:  
 
There are two recommended ways of upgrading the software on the Turbine station:  
Line 13: Line 13:
 
# Download and install the [[Downloads#VS-IMT_-_Intercom_management_Tool|VS-IMT tool]]
 
# Download and install the [[Downloads#VS-IMT_-_Intercom_management_Tool|VS-IMT tool]]
 
# Download the software package [[Downloads#Turbine_stations|tsi-3.0.3.5.zip]]. Don't unzip the file.
 
# Download the software package [[Downloads#Turbine_stations|tsi-3.0.3.5.zip]]. Don't unzip the file.
# Download the software package [[Downloads#Turbine_stations|sti-prod-4.2.3.6.zip]]. Don't unzip the file.
+
# Download the software package [[Downloads#Turbine_stations|sti-prod-4.2.3.9.zip]]. Don't unzip the file.
  
 
==== Upgrade procedure ====
 
==== Upgrade procedure ====
Line 31: Line 31:
 
* Now the software packages must be imported into the VS-IMT tool:
 
* Now the software packages must be imported into the VS-IMT tool:
 
** Select '''Import image...''', and browse to the '''tsi-3.0.3.5.zip''' file, and select '''Open'''  
 
** Select '''Import image...''', and browse to the '''tsi-3.0.3.5.zip''' file, and select '''Open'''  
** Select '''Import image...''' again, and browse to the '''sti-prod-4.2.3.6.zip''' file, and select '''Open'''  
+
** Select '''Import image...''' again, and browse to the '''sti-prod-4.2.3.9.zip''' file, and select '''Open'''  
  
 
* The next step is to upgrade the Turbine stations to 3.0.3.5:
 
* The next step is to upgrade the Turbine stations to 3.0.3.5:
Line 43: Line 43:
  
  
* The next step is to upgrade the Turbine stations to 4.2.3.6:
+
* The next step is to upgrade the Turbine stations to 4.2.3.9:
** Select the Turbine Image = '''sti.prod-4.2.3.6'''
+
** Select the Turbine Image = '''sti.prod-4.2.3.9'''
 
** Check the flag "''Enable upgrades requiring boot/environment version upgrade''"
 
** Check the flag "''Enable upgrades requiring boot/environment version upgrade''"
 
** In the list box, select the stations to upgrade. Use '''Ctrl + click''' to select multiple stations.
 
** In the list box, select the stations to upgrade. Use '''Ctrl + click''' to select multiple stations.
Line 58: Line 58:
 
# A TFTP Server must be available. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html.
 
# A TFTP Server must be available. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html.
 
# Download the software package '''tsi-3.0.3.5.zip''', and unzip the package and store the files in a folder on your PC.
 
# Download the software package '''tsi-3.0.3.5.zip''', and unzip the package and store the files in a folder on your PC.
# Download the software package '''sti-prod-4.2.3.6.zip''', and unzip the package and store the files in a different folder on your PC.
+
# Download the software package '''sti-prod-4.2.3.9.zip''', and unzip the package and store the files in a different folder on your PC.
 
# Check if your local firewall is '''not''' blocking incoming ping/ICMP  (Turbine station is pinging TFTP Server during update process)
 
# Check if your local firewall is '''not''' blocking incoming ping/ICMP  (Turbine station is pinging TFTP Server during update process)
  
Line 64: Line 64:
 
The upgrade is a two-step process:
 
The upgrade is a two-step process:
 
* First install version 3.0.3.5, then
 
* First install version 3.0.3.5, then
* Install version 4.2.3.6
+
* Install version 4.2.3.9
  
 
1. Start the TFTP server program and click '''Browse''', and select the folder where the version 3.0.3.5 software files are located
 
1. Start the TFTP server program and click '''Browse''', and select the folder where the version 3.0.3.5 software files are located
Line 83: Line 83:
  
  
When the station is up and running again, the next step is to install version 4.2.3.6:
+
When the station is up and running again, the next step is to install version 4.2.3.9:
  
5. In the TFTP server program, '''Browse''' to the folder where the version 4.2.3.6 software files are located
+
5. In the TFTP server program, '''Browse''' to the folder where the version 4.2.3.9 software files are located
  
6. In the Turbine web interface enter the image file: '''tsi2sti-4.2.3.6.ipk''', and '''Save settings'''
+
6. In the Turbine web interface enter the image file: '''tsi2sti-4.2.3.9.ipk''', and '''Save settings'''
  
[[File:TurbineTo 4236.PNG|thumb|left|500px|Installing '''tsi2sti-4.2.3.6.ipk''' via the station web interface]]
+
[[File:TurbineTo 4236.PNG|thumb|left|500px|Installing '''tsi2sti-4.2.3.9.ipk''' via the station web interface]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
Line 97: Line 97:
  
 
=== Upgrade using VS-IMT ===
 
=== Upgrade using VS-IMT ===
Turbine stations with software version 3.1.x.x, 4.0.x.x, 4.1.x.x or 4.2.x.x are upgraded using the '''sti-4.2.3.6''' package. Note that in some cases boot loader also need to be upgraded and it is necessary to enable such upgrades.
+
Turbine stations with software version 3.1.x.x, 4.0.x.x, 4.1.x.x or 4.2.x.x are upgraded using the '''sti-4.2.3.9''' package. Note that in some cases boot loader also need to be upgraded and it is necessary to enable such upgrades.
  
 
====Prerequisites====
 
====Prerequisites====
 
# Download and install the [[Downloads#VS-IMT_-_Intercom_management_Tool|VS-IMT tool]]
 
# Download and install the [[Downloads#VS-IMT_-_Intercom_management_Tool|VS-IMT tool]]
# Download the software package [[Downloads#Turbine_stations|sti-4.2.3.6.zip]]. Don't unzip the file.
+
# Download the software package [[Downloads#Turbine_stations|sti-4.2.3.9.zip]]. Don't unzip the file.
  
 
==== Upgrade procedure ====
 
==== Upgrade procedure ====
Line 110: Line 110:
 
* When the discovery process is finished, select all stations in the list by checking the '''Select All''' flag
 
* When the discovery process is finished, select all stations in the list by checking the '''Select All''' flag
 
* Press '''Next''' two times. You've now come to the "Upgrade Stations" window:
 
* Press '''Next''' two times. You've now come to the "Upgrade Stations" window:
* Import the image file into the VS-IMT tool by selecting '''Import image...''', and browse to the '''sti-4.2.3.6.zip''' file, and select '''Open'''  
+
* Import the image file into the VS-IMT tool by selecting '''Import image...''', and browse to the '''sti-4.2.3.9.zip''' file, and select '''Open'''  
* Select the Turbine Image = '''sti-4.2.3.6'''
+
* Select the Turbine Image = '''sti-4.2.3.9'''
 
* In the list box, select the stations to upgrade. Use '''Ctrl + click''' to select multiple stations.
 
* In the list box, select the stations to upgrade. Use '''Ctrl + click''' to select multiple stations.
 
* Press the '''Upgrade''' button to start the upgrade process. The status is shown on the screen. The Status will become '''''Success''''' when the station is up and running after the upgrade.
 
* Press the '''Upgrade''' button to start the upgrade process. The status is shown on the screen. The Status will become '''''Success''''' when the station is up and running after the upgrade.
Line 119: Line 119:
 
==== Upgrade TFIE/TFIX/TKIE (Turbine Industrial Stations) from version 3.1.x.x ====
 
==== Upgrade TFIE/TFIX/TKIE (Turbine Industrial Stations) from version 3.1.x.x ====
  
* [[Downloads#Turbine_station|Download]] the image file: sti-4.2.3.6.zip<br>
+
* [[Downloads#Turbine_station|Download]] the image file: sti-4.2.3.9.zip<br>
 
* Unzip the file to a folder
 
* Unzip the file to a folder
 
* Start the TFTP server program and '''Browse''' to the folder where the files are located  
 
* Start the TFTP server program and '''Browse''' to the folder where the files are located  
Line 126: Line 126:
 
From the Station web page, '''Station Administration''' > '''Manual Upgrade''', enter:
 
From the Station web page, '''Station Administration''' > '''Manual Upgrade''', enter:
  
# Image file: '''boot/sti-4.2.3.6'''
+
# Image file: '''boot/sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)
# Image file: '''sti-4.2.3.6'''
+
# Image file: '''sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)
Line 135: Line 135:
 
==== Upgrade TCIV (Turbine Video station) from version 4.0.x.x or 4.1.x.x ====
 
==== Upgrade TCIV (Turbine Video station) from version 4.0.x.x or 4.1.x.x ====
  
* [[Downloads#Turbine_station|Download]] the image file: sti-4.2.3.6.zip<br>
+
* [[Downloads#Turbine_station|Download]] the image file: sti-4.2.3.9.zip<br>
 
* Unzip the file to a folder
 
* Unzip the file to a folder
 
* Start the TFTP server program and '''Browse''' to the folder where the files are located  
 
* Start the TFTP server program and '''Browse''' to the folder where the files are located  
Line 142: Line 142:
 
From the Station web page, '''Station Administration''' > '''Manual Upgrade''', enter:
 
From the Station web page, '''Station Administration''' > '''Manual Upgrade''', enter:
  
# Image file: '''boot/sti-4.2.3.6'''
+
# Image file: '''boot/sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)
# Image file: '''video/sti-4.2.3.6'''
+
# Image file: '''video/sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)
# Image file: '''sti-4.2.3.6'''
+
# Image file: '''sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)
  
Note! after the step '''video/sti-4.2.3.6''' you will probably have no intercom service running and now detailed version info in web. That is ok, just continue to next upgrade step '''sti-4.2.3.6''' and all should be ok in the end.
+
Note! after the step '''video/sti-4.2.3.9''' you will probably have no intercom service running and now detailed version info in web. That is ok, just continue to next upgrade step '''sti-4.2.3.9''' and all should be ok in the end.
  
 
==== Upgrade TMIS (Turbine Mini) from version 4.1.x.x ====
 
==== Upgrade TMIS (Turbine Mini) from version 4.1.x.x ====
  
* [[Downloads#Turbine_station|Download]] the image file: sti-4.2.3.6.zip<br>
+
* [[Downloads#Turbine_station|Download]] the image file: sti-4.2.3.9.zip<br>
 
* Unzip the file to a folder
 
* Unzip the file to a folder
 
* Start the TFTP server program and '''Browse''' to the folder where the files are located  
 
* Start the TFTP server program and '''Browse''' to the folder where the files are located  
Line 163: Line 163:
 
From the Station web page, '''Station Administration''' > '''Manual Upgrade''', enter:
 
From the Station web page, '''Station Administration''' > '''Manual Upgrade''', enter:
  
# Image file: '''boot/sti-4.2.3.6'''
+
# Image file: '''boot/sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)
# Image file: '''sti-4.2.3.6'''
+
# Image file: '''sti-4.2.3.9'''
 
# '''Save Settings'''
 
# '''Save Settings'''
 
# '''Upgrade''' (Turbine will restart)
 
# '''Upgrade''' (Turbine will restart)

Revision as of 15:03, 4 May 2016

This article describes how to upgrade the software of the Turbine series of intercom devices to version 4.2.3.9. Note that there is a separate Upgrade procedure for INCA IP stations.

There are two recommended ways of upgrading the software on the Turbine station:

The VS-IMT tool allows mass upgrade of stations.

Upgrade TCIS or TKIS-2 (Turbine Compact) from version 3.0.x.x

Upgrade using the VS-IMT tool

Prerequisites

  1. Download and install the VS-IMT tool
  2. Download the software package tsi-3.0.3.5.zip. Don't unzip the file.
  3. Download the software package sti-prod-4.2.3.9.zip. Don't unzip the file.

Upgrade procedure

  • Start the VS-IMT tool
  • Select Create project or open an existing project, and start the wizard that takes you through the discovery and upgrade process, by selecting File > Launch Station Wizard
  • Press Next to go to Station Discovery. Enter the range of IP addresses (From - To) to search for, and press Search
  • When the discovery process is finished, select all stations in the list by checking the Select All flag
Station Discovery window


  • Press Next two times. You've now come to the "Upgrade Stations" window:
The Upgrade Stations window


  • Now the software packages must be imported into the VS-IMT tool:
    • Select Import image..., and browse to the tsi-3.0.3.5.zip file, and select Open
    • Select Import image... again, and browse to the sti-prod-4.2.3.9.zip file, and select Open
  • The next step is to upgrade the Turbine stations to 3.0.3.5:
    • Select the Turbine Image = tsi-3.0.3.5
    • In the list box, select the stations to upgrade. Use Ctrl + click to select multiple stations.
Turbine image and stations selected, ready to start the upgrade


  • Press the Upgrade button to start the upgrade process. The status is shown on the screen. The Status will become Success when the station is up and running after the upgrade.


  • The next step is to upgrade the Turbine stations to 4.2.3.9:
    • Select the Turbine Image = sti.prod-4.2.3.9
    • Check the flag "Enable upgrades requiring boot/environment version upgrade"
    • In the list box, select the stations to upgrade. Use Ctrl + click to select multiple stations.
Turbine image and stations selected, upgrade in process


  • Press the Upgrade button to start the upgrade process. The status is shown on the screen. The Status will become Success when the station is up and running after the upgrade.

Upgrade using the Web Interface of the station

Prerequisites

  1. A TFTP Server must be available. A TFTP server can be downloaded from here: http://tftpd32.jounin.net/tftpd32_download.html.
  2. Download the software package tsi-3.0.3.5.zip, and unzip the package and store the files in a folder on your PC.
  3. Download the software package sti-prod-4.2.3.9.zip, and unzip the package and store the files in a different folder on your PC.
  4. Check if your local firewall is not blocking incoming ping/ICMP (Turbine station is pinging TFTP Server during update process)

Upgrade procedure

The upgrade is a two-step process:

  • First install version 3.0.3.5, then
  • Install version 4.2.3.9

1. Start the TFTP server program and click Browse, and select the folder where the version 3.0.3.5 software files are located

TFTP Server - Browse to the folder where the software files are located


2. Log on to the Turbine Station web interface. Default login credentials are admin and alphaadmin. Select Station Administration > Manual Upgrade

3. Enter the IP address of the TFTP server (I.e. the IP address of your PC)

4. Enter the image file: tsi-3.0.3.5, and click Save settings

Load tsi-3.0.3.5 via the station web interface


The station will now contact the TFTP server and download the files. The upgrade procedure takes about 3 minutes. The process can be monitored by clicking the Log viewer tab in the TFTP server program.


When the station is up and running again, the next step is to install version 4.2.3.9:

5. In the TFTP server program, Browse to the folder where the version 4.2.3.9 software files are located

6. In the Turbine web interface enter the image file: tsi2sti-4.2.3.9.ipk, and Save settings

Installing tsi2sti-4.2.3.9.ipk via the station web interface


The station will again contact the TFTP server and download and install the required files.

Upgrade Turbine stations from 3.1, 4.0, 4.1 or 4.2

Upgrade using VS-IMT

Turbine stations with software version 3.1.x.x, 4.0.x.x, 4.1.x.x or 4.2.x.x are upgraded using the sti-4.2.3.9 package. Note that in some cases boot loader also need to be upgraded and it is necessary to enable such upgrades.

Prerequisites

  1. Download and install the VS-IMT tool
  2. Download the software package sti-4.2.3.9.zip. Don't unzip the file.

Upgrade procedure

  • Start the VS-IMT tool
  • Select Create project or open an existing project, and start the wizard that takes you through the discovery and upgrade process, by selecting File > Launch Station Wizard
  • Press Next to go to Station Discovery. Enter the range of IP addresses (From - To) to search for, and press Search
  • When the discovery process is finished, select all stations in the list by checking the Select All flag
  • Press Next two times. You've now come to the "Upgrade Stations" window:
  • Import the image file into the VS-IMT tool by selecting Import image..., and browse to the sti-4.2.3.9.zip file, and select Open
  • Select the Turbine Image = sti-4.2.3.9
  • In the list box, select the stations to upgrade. Use Ctrl + click to select multiple stations.
  • Press the Upgrade button to start the upgrade process. The status is shown on the screen. The Status will become Success when the station is up and running after the upgrade.



Manual Upgrade from Station Web

Upgrade TFIE/TFIX/TKIE (Turbine Industrial Stations) from version 3.1.x.x

  • Download the image file: sti-4.2.3.9.zip
  • Unzip the file to a folder
  • Start the TFTP server program and Browse to the folder where the files are located

Upgrade process:
From the Station web page, Station Administration > Manual Upgrade, enter:

  1. Image file: boot/sti-4.2.3.9
  2. Save Settings
  3. Upgrade (Turbine will restart)
  4. Image file: sti-4.2.3.9
  5. Save Settings
  6. Upgrade (Turbine will restart)

Upgrade TCIV (Turbine Video station) from version 4.0.x.x or 4.1.x.x

  • Download the image file: sti-4.2.3.9.zip
  • Unzip the file to a folder
  • Start the TFTP server program and Browse to the folder where the files are located

Upgrade process:
From the Station web page, Station Administration > Manual Upgrade, enter:

  1. Image file: boot/sti-4.2.3.9
  2. Save Settings
  3. Upgrade (Turbine will restart)
  4. Image file: video/sti-4.2.3.9
  5. Save Settings
  6. Upgrade (Turbine will restart)
  7. Image file: sti-4.2.3.9
  8. Save Settings
  9. Upgrade (Turbine will restart)

Note! after the step video/sti-4.2.3.9 you will probably have no intercom service running and now detailed version info in web. That is ok, just continue to next upgrade step sti-4.2.3.9 and all should be ok in the end.

Upgrade TMIS (Turbine Mini) from version 4.1.x.x

  • Download the image file: sti-4.2.3.9.zip
  • Unzip the file to a folder
  • Start the TFTP server program and Browse to the folder where the files are located

Upgrade process:
From the Station web page, Station Administration > Manual Upgrade, enter:

  1. Image file: boot/sti-4.2.3.9
  2. Save Settings
  3. Upgrade (Turbine will restart)
  4. Image file: sti-4.2.3.9
  5. Save Settings
  6. Upgrade (Turbine will restart)

Troubleshooting

In the case the upgrade is not successful it may be due to a windows setting.