Difference between revisions of "IP Flush Master and Headset"
From Zenitel Wiki
Line 1: | Line 1: | ||
{{stub}} | {{stub}} | ||
This article describes how to connect headset to the [[IP Flush Master - 1008031000]]. | This article describes how to connect headset to the [[IP Flush Master - 1008031000]]. | ||
− | |||
− | |||
[[File:IPFlush Headset.PNG|thumb|500px|Headset AK5058HS IP Flush Master]] | [[File:IPFlush Headset.PNG|thumb|500px|Headset AK5058HS IP Flush Master]] | ||
There are two main hardware revisions of the Handset 1008071000 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows: | There are two main hardware revisions of the Handset 1008071000 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows: |
Revision as of 12:45, 6 January 2015
This article describes how to connect headset to the IP Flush Master - 1008031000.
There are two main hardware revisions of the Handset 1008071000 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows:
Handset revision 1008071000.0300 or newer (from May 2013)
- Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
- Used with IP Flush Master revision 1008031000.0301 or older:
- Update the software of the IP Flush Master to version 02.3.3.1 or later
- Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
- Connect the Handset to the HEADSET-connector of the station
Handset revision 1008071000.0201 or older
- Used with IP Flush Master revision 1008031000.0301 or older: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
- Used with IP Flush Master revision 1008031000.0400 or newer:
- Upgrade the handset to revision 0300 by dismantling the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image.
- Connect the handset to the handset connector of the station.
About noise in the ear-piece of the handset
When handset revision 1008071000.0201 or older is used with IP Flush Master revision 1008031000.0301 or older, one might experience noise in the ear-piece of the handset. This can be improved by upgrading the handset to revision 1008071000.0300, and use the headset connector of the station.
Procedure:
- Dismantle the handset by unscrewing the two screws
- Flip the circuit board over and solder a strap as shown in the image
- Update the software of the IP Flush Master to version 02.3.3.1 or later
- Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
- Connect the handset to the HEADSET-connector of the station
NOTE: The option to use the headset input also for handset is a workaround available in AlphaCom-mode only.