=Reset to Factory Default Settings with Activated DHCP= | =Reset to Factory Default Settings with Activated DHCP= | ||
− | [[File:TFIX SpeakeIP 1.png|thumb| | + | [[File:TFIX SpeakeIP 1.png|thumb|130px|Factory Default with IP address from DHCP server]] |
To reset: | To reset: | ||
:1. While '''pressing any button''', power up the station. | :1. While '''pressing any button''', power up the station. | ||
Line 20: | Line 20: | ||
=Reset to Factory Default Settings with Static IP= | =Reset to Factory Default Settings with Static IP= | ||
− | [[File:TFIX SpeakeIP 2.png|thumb| | + | [[File:TFIX SpeakeIP 2.png|thumb|130px|Factory Default with Static IP Address]] |
To reset: | To reset: | ||
:1. While '''pressing any button''', power up the station. | :1. While '''pressing any button''', power up the station. |
Revision as of 14:04, 2 February 2017
A Turbine EX Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
NOTE! A TFIX Factory Default will also reset the Flowire NMK password. See here for more
Reset to Factory Default Settings with Activated DHCP
To reset:
- 1. While pressing any button, power up the station.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 5 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button to make the station say its IP address.
Factory default values
- Station IP address: (determined by DHCP server)
- Username: admin
- Password: alphaadmin
Reset to Factory Default Settings with Static IP
To reset:
- 1. While pressing any button, power up the station.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 3 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button to make the station say its IP address.
Factory default values
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin