== Gooseneck Microphone for IP Dual Display ==
 
[[File:IP_Dual_Display_Gooseneck_Microphone.PNG|thumb|IP Dual Display Gooseneck Microphone]]
 
:* Item number: 1007007010
 
This item applies to the IP Dual Display Station only.
 
<br/>
 
<u>'''To install the Gooseneck Microphone:'''</u>
 
* Flip the station over so that the bottom side is facing up
 
* Slide the tab on the microphone foot into the slot on the side of the station
 
* Secure the microphone foot to the station with a screw as shown
 
* Plug the microphone jack into the socket just above the RJ45 port
 
[[File:IP Dual Display Gooseneck Microphone Installation.PNG|thumb|left|600px|Installing the Gooseneck Microphone for Dual Display]] <br/>
 
<br style="clear:both;" />
 
The internal microphone is automatically disconnected when the gooseneck microphone jack is inserted.
 
 
 
See also: [[IP Dual Display station: Noise from gooseneck mic]]
 
  
 
== Input/Output Connections ==
 
== Input/Output Connections ==

Revision as of 12:43, 20 October 2016

Introduction

The table below is an overview of the main connectors involved when installing the IP Flush Master Stations.

LAN 10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX 10/100 Mbps RJ-45 ports for auxiliary equipment such as PC and IP camera.
Handset Port RJ11
Headset Port RJ11
Input/Output Pluggable screw terminal
Extension Unit (IP DAK-48) RJ45
Local Power Plugable screw terminal, 19-27 VDC Idle 4W, max. 8W

Power Supply

The IP Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Flush Master Station can be connected to a 24 VDC local power supply.

See Related Article IP Flush Master Station Board Connections for local power supply connections.

Network Connection

There are two RJ45 ports on the IP Stations:

  • LAN port: for connecting to the network and the AlphaCom XE Audio Server.
  • AUX port: for connecting to auxiliary equipment such as a PC or IP Camera.
IP Flush Master, IP OR, IP Master Kit - Rear view

Input/Output Connections

There are I/O connection options for all IP Stations, except the IP Desktop Station and the IP Dual Display Station. These I/O connections include:

  • 3 digital inputs (P4)
  • 1 logical output (TP9)
  • 1 relay output (P3)


These connections are used as relay contacts for door lock control and external I/O devices. For pin settings on the P3 and P4 connectors on the station board, see See Related Article IP Station Board Connections and Indications.